LERBAKKEN 10, 8410 RØNDE DENMARK
Module 9203B1A & 9203B1B
Terminal 41-42 / 51-52
Uo/Voc
28 V
IIC or A,B
Io/Isc
93 mA
IIB or C,E,F
Po
0.65 W
IIA or D,G
Module 9203B1A & 9203B1B
Terminal 41-43 / 51-53
Uo/Voc
28 V
IIC or A,B
Io/Isc
100 mA
IIB or C,E,F
Po
0.70 W
IIA or D,G
Module 9203B1A & 9203B1B
Terminal 41-44 / 51-54
Uo/Voc
28 V
IIC or A,B
Io/Isc
110 mA
IIB or C,E,F
Po
0.77 W
IIA or D,G
Terminal (31,32)
Supply:
Voltage
Power max.
Terminal (33,34)
Status Relay:
Voltage max.
Power max.
Current max.
Installation notes:
The installation and wiring shall be in accordance with the Canadian Electrical Code for Canada and
National Electrical Code NFPA 70, Article 500 or 505 for installation in USA.
The module must be supplied from a Power Supply having double or reinforced insulation.
The use of stranded wires is not permitted for mains wiring except when wires are fitted with cable
ends.
For installation on the 9400 Power Rail the power must be supplied from Power Control Module Unit
9410.
Install in pollution degree 2, overvoltage category II.
The module must be installed in an enclosure suitable for the environment for which it is used.
For installation in Zone 2 or Division 2, the module must be installed in a suitable outer enclosure
according to the regulations in the CEC for Canada or NEC for USA.
The module is galvanically isolated and does not require grounding.
Use 60 / 75 ºC copper conductors with wire size AWG: (26-14).
The maximum internal Power dissipation for adjacent modules is assumed to be max. 2W each.
Warning: Substitution of components may impair intrinsic safety and / or suitability for Div. 2 / Zone 2.
Warning: To prevent ignition of explosive atmospheres, disconnect power before servicing and do not
separate connectors when energized and an explosive gas mixture is present.
Warning: Do not mount or remove modules from the Power Rail when an explosive gas mixture is
present.
Revision date:
2011-11-20
Lo/Ro or
Co/Ca
Lo/La
La/Ra
80 nF
4.2 mH
54 μH/Ω
640 nF
16.8 mH 218 μH/Ω
2.1 μF
32.6 mH 436 μH/Ω
Lo/Ro or
Co/Ca
Lo/La
La/Ra
80 nF
3.5 mH
50 μH/Ω
640 nF
14.2 mH 201 μH/Ω
2.1 μF
27.6 mH 402 μH/Ω
Lo/Ro or
Co/Ca
Lo/La
La/Ra
80 nF
2.9 mH
46 μH/Ω
640 nF
11.8 mH 184 μH/Ω
2.1 μF
22.8 mH 369 μH/Ω
19.2 – 31.2 VDC
3.5 W
Non Hazardous location: Division 2 or Zone 2 installation:
125 VAC / 110 VDC
62.5 VA / 32 W
0.5 AAC / 0.3 ADC
Version Revision
V5 R0
9203 - Product Version 9203-002
Module 9203B2A
Co/Ca
Terminal 41-42
Uo/Voc
28 V
80 nF
IIC or A,B
Io/Isc
115 mA
640 nF
IIB or C,E,F
Po
0.81 W
2.1 μF
IIA or D,G
Module 9203B2A
Co/Ca
Terminal 41-43
Uo/Voc
28 V
IIC or A,B
Io/Isc
125 mA
640 nF
IIB or C,E,F
Po
0.88 W
2.1 μF
IIA or D,G
Module 9203B2A
Co/Ca
Terminal 41-44
Uo/Voc
28 V
IIC or A,B
Io/Isc
135 mA
640 nF
IIB or C,E,F
Po
0.95 W
2.1 μF
IIA or D,G
Terminal (11,12 and 13,14)
Input:
Voltage
max 28VDC
Trig: NPN
Low < 2V, High > 4V
Trig: PNP
Low < 8V, High > 10V
32 VAC / 32VDC
16 VA / 32 W
0.5 AAC / 1 ADC
Prepared by:
PB
9203QF01
Lo/Ro or
Lo/La
La/Ra
2.69 mH
44 μH/Ω
10.8 mH 176 μH/Ω
20.8 mH 353 μH/Ω
Lo/Ro or
Lo/La
La/Ra
9.1 mH
163 μH/Ω
17.6 mH 327 μH/Ω
Lo/Ro or
Lo/La
La/Ra
7.8 mH
150 μH/Ω
15.1 mH 301 μH/Ω
Page:
2/2
27