8.1.a ADJUSTING DISPENSED QUANTITY (Fig. 11)
‼
IMPORTANT:
•
the operations described below must be performed by a specialized technician, and only after
disconnecting the appliance from the electricity mains
•
all operations that require handling of parts made of metal plate must be carried out wearing
suitable gloves to prevent cuts
The appliance is provided with an electronic device for adjusting the quantity of ice dispensed each
time.
To increase or decrease the dispensing time and the proportionate quantity of ice dispensed,
proceed as follows:
• remove the basin (20)
• slacken off the screws (21) on the front panel using a Phillips screwdriver
• pull out the front panel from above
• turn the knob (22) on the electronic device clockwise to increase the quantity of ice dispensed
whenever the button is pressed, and anti-clockwise to reduce the quantity
8.2 MODEL WITH COLD WATER DISPENSER (Fig. 12)
The appliance is provided with a cold water dispenser located beside the ice bin.
To obtain cold water, place a glass under the outlet and gently press the button (23) to turn on the water
tap. Release the button to stop the flow of cold water.
If the appliance is already provided with a filter located on the cold water supply circuit, read the
instructions on the filter label carefully and follow the manufacturer's recommendations regarding the
replacement schedules.
9.1 CLEANING THE FILTER OF WATER SUPPLY SOLENOID VALVE (Fig. 13)
!!
At least every two months, clean the filter (24) located on the water inlet solenoid valve, proceeding
as follows:
• switch off the electric power supply by means of the switch (7 in Fig. 4), fitted during installation,
and disconnect the plug of the appliance from its socket (if any)
• shut off the water supply by turning the tap (8 in Fig. 4) fitted during installation
• unscrew the threaded ring nut (14) of the water feed hose, located at the outlet of the solenoid valve at
the rear of the appliance (front for the flush-mounting models). For the built-in model, first remove
the panel as indicated at point 5.2.a
• using a pair of pliers, remove the filter (24) from its seat without damaging the water feed pipe
connector
• place the filter under a strong jet of water to remove residue, but replace the filter if it is excessively
dirty
After having carried out the cleaning operations, refit the filter and hose pipe taking the necessary
precautions described earlier in the instruction manual.
When the operations have terminated, turn on both the electricity supply and water supply.
9.2 AIR-COOLED MODELS (Fig. 14)
For air-cooled models, it is very important to keep the finned condenser and its external filter (if any) clean.
Have the finned condenser cleaned at least once every two months by an Authorized Technical Service
Centre, which can include this operation in the scheduled maintenance programme.
The external filter (if any) must be cleaned at least once a month, as follows:
• switch off appliance and cut off power supply with the switch (7 in Fig. 4) fitted at the installation stage
• open plastic grille
• remove filter and keep it at a distance form the appliance
• remove dust from filter by blowing with compressed air
• replace filter in its seat and close plastic grille
9 MAINTENANCE