Descargar Imprimir esta página

Publicidad

Enlaces rápidos

FCC / IC
En
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user's authority
to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance requirements, no change to
the antenna or the device is permitted. Any change to the antenna or the device could result in
the device exceeding the RF exposure requirements and void user's authority to operate the
device.
Fr
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils
exempts de licence d'Industrie Canada. Son utilisation est sujette aux deux conditions
suivantes : 1) cet appareil ne doit pas occasionner de brouillage préjudiciable et 2) cet appareil
doit accepter toutes les interférences reçues, notamment les interférences qui peuvent
provoquer un fonctionnement non désiré.
NOTE DE LA FCC : Le fabricant n'est pas responsable des interférences sur les fréquences
radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées de
ce matériel. De telles modifications peuvent annuler le droit de l'utilisateur à utiliser cet appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites ont
été définies afin de fournir une protection raisonnable contre le brouillage préjudiciable en milieu
résidentiel. Cet appareil produit, utilise et peut émettre des ondes de fréquence radio et, s'il n'est
pas installé et utilisé conformément aux instructions, il peut provoquer un brouillage préjudiciable
aux communications radio. Il n'existe toutefois aucune garantie que des interférences ne se
produiront pas au sein d'une installation donnée. Si cet appareil occasionne un brouillage
préjudiciable à la réception radiophonique ou télévisuelle, il suffit d'allumer et d'éteindre
l'appareil pour déterminer sa responsabilité. Nous encourageons l'utilisateur à essayer de
corriger ces interférences en appliquant une ou plusieurs des mesures suivantes :
— Réorienter ou déplacer l'antenne de réception.
— Augmenter la distance entre l'appareil et le récepteur.
— Brancher l'appareil à une prise secteur différente de celle du récepteur.
— Consulter le revendeur ou un technicien spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la FCC concernant
l'exposition aux RF, aucune modification apportée à l'antenne ou au dispositif n'est autorisée.
Toute modification apportée à l'antenne ou au dispositif pourrait faire en sorte que le dispositif
dépasse les exigences d'exposition aux RF et pourrait annuler le droit de l'utilisateur à utiliser
ce dispositif.
Es
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de la FCC
y con las especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria
de Canadá aplicables a aparatos exentos de licencia. El funcionamiento está sujeto a las
siguientes dos condiciones: (1) este dispositivo no debe provocar interferencia perjudicial, y (2)
este dispositivo debe aceptar toda interferencia que reciba, incluso la que pudiera causar un
funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio
o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo. Dichas
modificaciones podrían anular la autoridad del usuario para utilizar el equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales de
Clase B, de conformidad con el apartado 15 de las normas de la FCC. Estos límites están
diseñados para proveer protección razonable contra interferencias perjudiciales en una
instalación residencial. Este equipo genera, usa y puede irradiar energía de radiofrecuencias
y, si no se instala y usa según las instrucciones, puede provocar interferencia perjudicial a las
radiocomunicaciones. No obstante, no hay garantías de que no ocurrirá interferencia en una
instalación en particular. Si este equipo provoca interferencia perjudicial a la recepción de radio
o televisión, lo que puede determinarse encendiendo y apagando el equipo, se recomienda que
el usuario intente corregir la interferencia por medio de la implementación de una o más de las
siguientes medidas:
— Reorientar o reubicar la antena receptora.
— Incrementar la separación entre el equipo y el receptor.
— Conectar el equipo a un tomacorriente de un circuito diferente del circuito al que está
conectado el receptor.
— Consultar al distribuidor o a un técnico con experiencia en radio/televisión para
solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
FCC — U2ZZW4003A | IC: 6924A-ZW4003A
Jasco Products Company | Model: ZW4003 / 14319
CAN ICES-3(B) / NMB-3(B)
All brand names shown are trademarks of their
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
respective owners.
DISTRIBUTED BY JASCO PRODUCTS COMPANY LLC,
Tous les noms de marque illustrés sont des
10 E. MEMORIAL RD., OKLAHOMA CITY, OK
marques de commerce de leurs propriétaires
©JASCO 2016 | 14319 | ZW4003 | rev. 11/22/16 RT v1
respectifs.
Todas las marcas que aparecen aquí son marcas
registradas de sus respectivos dueños.
1.
Tools you will need
IMPORTANT!
The fixture controlled by the Z-Wave In-Wall Smart Switch must not exceed
960 watts (Incandescent). The switch is designed only for use with permanently
installed fixtures.
Getting to know your new Z-Wave device
• Turn ON/OFF manually or remotely via the Z-Wave controller
• Can be included in multiple Groups and Scenes
• May be used in single pole installation or with up to two Jasco Add-on switches
in 3-way or 4-way wiring configurations
• Compatible with all incandescent and CFL/LED bulbs
• Uses a standard, toggle wallplate for single gang installations
(wallplate not included)
• Z-Wave Certified for simple pairing and integrated home automation
• Screw Terminal Installation — requires wiring connections for Line (Hot), Load,
Neutral and Ground. Traveler wire required for 3-way or 4-way installation
• This Z-Wave device has advanced features that allow you to customize your
experience. These features can only be adjusted by a Z-Wave enabled controller
that support the Z-Wave Configuration command class. For a complete list of
Adjustable Configurations, visit: www.byjasco.com/z-waveconfig
2.
A
F
B
D
G
C
E
A. Ground (Green/Bare)
E. Neutral (White)
B. Load (Black)
F. Up — (Press up & release to turn
switch on)
C. Line (Black)
G. Down — (Press down & release
D. Traveler (Red/Other)
to turn switch off)
Single, dual and triple gang boxes
When installing the In-Wall Smart Switch in multiple gang boxes it may
be necessary to break off one or both sides of the scored tabs on the
front yoke. This does not affect the electrical rating of the switch (see
specifications for details).
MANUAL • MANUEL •
MANUAL
In-Wall
Smart Switch
Interrupteur
intelligent
mural
Interruptor
de pared
inteligente
Scan to view
installation guide
Balayez ce code pour
consulter le guide
d'installation.
Escanear para ver
ezzwave.com
la guía de instalación
Z-Wave
Certified Wireless Lighting Control
®
Certifié Z-Wave
Commande d'éclairage sans fil
®
Control inalámbrico para iluminación certificado por Z-Wave
®
3.
OR
OR
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the
service panel. All wiring connections must be made with the POWER OFF to
avoid personal injury and/or damage to the switch. This device is intended for
installation in accordance with the National Electric Code and local regulations
in the United States, or the Canadian Electrical Code and local regulations in
Canada. If you are unsure or uncomfortable about performing this installation
consult a qualified electrician.
Multi-switch wiring
For 3-way installations, please refer to Add-on Switch (45741/45761) manual
1. Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2. Remove wallplate.
3. Remove the switch mounting screws.
4. Carefully remove the switch from the switch
box. DO NOT disconnect the wires.
5. There are up to five screw terminals on the switch; these are marked:
A. LINE (Hot) — Black (connected to power)
B. NEUTRAL — White
C. LOAD — Black (connected to lighting)
4.
Adding your device to a Z-Wave network:
1. Follow the instructions for your Z-Wave certified controller to add a device to the
Z-Wave network.
2. Once the controller is ready to add your device, press up and release the toggle
to add it in the network.
Please reference the controller's manual for instructions.
Now you have complete control to turn your fixture ON/OFF or dim according
to groups, scenes, schedules and interactive automations programmed by your
controller.
If your Z-Wave certified controller features Remote Access, you can now control
your fixture from your mobile devices.
DO NOT RETURN THIS
PRODUCT TO THE STORE
STOP
NE RETOURNEZ PAS
CE PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
If you have any problems or questions, contact our tech support team at
1-800-654-8483, (option 1) Monday–Friday, 7AM–8PM CST.
For the most up-to-date product support, accessories, electronic (PDF) format
manuals and more, visit www.byjasco.com/support.
• No user serviceable parts in this unit.
Si vous avez des problèmes ou des questions, communiquez avec notre
équipe de soutien technique au 1-800-654-8483, option 1, du lundi au vendredi,
de 7 h à 20 h (HNC).
Pour le soutien relatif aux produits le plus à jour, les accessoires, les manuels
en format électronique (PDF) et plus encore, visitez le site www.byjasco.com/
support.
• Aucune des pièces de ce dispositif ne peut être réparée par l'utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro equipo técnico al número:
1-800-654-8483, opción 1 de lunes a viernes, de 7 a.m. a 8 p.m., hora estándar
del centro (CST).
Para recibir el soporte técnico más actualizado sobre productos, accesorios,
manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
WARNING
ADVERTENCIA
RISK OF FIRE
RIESGO DE INCENDIO
RISK OF ELECTRICAL SHOCK
RIESGO DE DESCARGA ELÉCTRICA
RISK OF BURNS
RIESGO DE QUEMADURAS
CONTROLLING APPLIANCES:
CONTROL DE EQUIPOS
EXERCISE EXTREME CAUTION WHEN
ELECTRODOMÉSTICOS:
USING Z-WAVE DEVICES TO CONTROL
PROCEDA CON SUMA PRECAUCIÓN AL USAR
APPLIANCES. OPERATION OF THE Z-WAVE
LOS DISPOSITIVOS Z-WAVE PARA CONTROLAR
DEVICE MAY BE IN A DIFFERENT ROOM
EQUIPOS ELECTRODOMÉSTICOS. EL
THAN THE CONTROLLED APPLIANCE,
DISPOSITIVO Z-WAVE PUEDE FUNCIONAR EN
ALSO AN UNINTENTIONAL ACTIVATION MAY
UNA HABITACIÓN DIFERENTE A LA DEL EQUIPO
OCCUR IF THE WRONG BUTTON ON THE
CONTROLADO. ADEMÁS, PODRÍA PRODUCIRSE
REMOTE IS PRESSED. Z-WAVE DEVICES MAY
UNA ACTIVACIÓN ACCIDENTAL SI SE OPRIME
AUTOMATICALLY BE POWERED ON DUE TO
EL BOTÓN INCORRECTO EN EL CONTROL
TIMED EVENT PROGRAMMING. DEPENDING
REMOTO. LOS DISPOSITIVOS Z-WAVE PUEDEN
UPON THE APPLIANCE, THESE UNATTENDED
ENCENDERSE AUTOMÁTICAMENTE DEBIDO A
OR UNINTENTIONAL OPERATIONS COULD
EVENTOS CRONOMETRADOS PROGRAMADOS.
POSSIBLY RESULT IN A HAZARDOUS
SEGÚN EL EQUIPO DEL QUE SE TRATE,
CONDITION. FOR THESE REASONS, WE
ESTE FUNCIONAMIENTO ACCIDENTAL O
RECOMMEND THE FOLLOWING:
SIN SUPERVISIÓN PODRÍA CREAR UNA
SITUACIÓN PELIGROSA. POR TALES MOTIVOS,
DO NOT USE Z-WAVE DEVICES TO CONTROL
ELECTRIC HEATERS OR ANY OTHER
RECOMENDAMOS LO SIGUIENTE:
APPLIANCES WHICH MAY PRESENT
NO USAR LOS DISPOSITIVOS Z-WAVE PARA
A HAZARDOUS CONDITION DUE TO
CONTROLAR CALENTADORES ELÉCTRICOS
UNATTENDED OR UNINTENTIONAL OR
U OTROS APARATOS ELECTRODOMÉSTICOS
AUTOMATIC POWER ON CONTROL.
QUE PUDIERAN IMPLICAR UN PELIGRO
DEBIDO A UN ENCENDIDO SIN SUPERVISIÓN,
AVERTISSEMENT
ACCIDENTAL O AUTOMÁTICO.
RISQUE D'INCENDIE
RISQUE DE CHOC ÉLECTRIQUE
NOT FOR USE WITH MEDICAL OR
RISQUE DE BRÛLURES
LIFE SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD NEVER
COMMANDE DES APPAREILS :
BE USED TO SUPPLY POWER TO, OR
CONTROL THE ON/OFF STATUS OF MEDICAL
SOYEZ TRÈS PRUDENT LORSQUE VOUS
UTILISEZ LES DISPOSITIFS Z-WAVE POUR
AND/OR LIFE SUPPORT EQUIPMENT.
COMMANDER LES APPAREILS. LE DISPOSITIF
Z-WAVE PEUT ÊTRE UTILISÉ DANS UNE SALLE
NE PAS UTILISER AVEC UN ÉQUIPEMENT
DIFFÉRENTE DE CELLE DANS LAQUELLE SE
MÉDICAL OU DE SURVIE
TROUVE L'APPAREIL COMMANDÉ ET UNE
LES DISPOSITIFS COMPATIBLES AVEC LA
ACTIVATION INVOLONTAIRE PEUT AUSSI
TECHNOLOGIE Z-WAVE NE DEVRAIENT
SE PRODUIRE SI LE MAUVAIS BOUTON
JAMAIS ÊTRE UTILISÉS POUR ALIMENTER OU
EST ACTIVÉ SUR LA TÉLÉCOMMANDE. LES
DISPOSITIFS Z-WAVE POURRAIENT ÊTRE
COMMANDER LA MISE EN MARCHE OU L'ARRÊT
DE L'ÉQUIPEMENT MÉDICAL OU DE SURVIE.
ACTIVÉS AUTOMATIQUEMENT À CAUSE D'UN
ÉVÉNEMENT PROGRAMMÉ. SELON L'APPAREIL,
CES UTILISATIONS INVOLONTAIRES ET
SE PROHÍBE SU EMPLEO EN
SANS SUPERVISION PEUVENT ENGENDRER
EQUIPO MÉDICO O EQUIPO
UN RISQUE. POUR CES RAISONS, NOUS
PARA EL MANTENIMIENTO DE
RECOMMANDONS CE QUI SUIT :
LAS FUNCIONES VITALES
N'UTILISEZ PAS LES DISPOSITIFS Z-WAVE
LOS DISPOSITIVOS Z-WAVE NUNCA SE
POUR COMMANDER LES RADIATEURS
DEBEN USAR PARA SUMINISTRAR ENERGÍA
ÉLECTRIQUES OU D'AUTRES APPAREILS
ELÉCTRICA AL EQUIPO MÉDICO O AL EQUIPO
QUI POURRAIENT PRÉSENTER UN DANGER
PARA EL MANTENIMIENTO DE FUNCIONES
EN CAS DE COMMANDE D'ACTIVATION
VITALES, NI PARA CONTROLAR EL ESTADO DE
IMPRÉVUE, INVOLONTAIRE OU AUTOMATIQUE.
ENCENDIDO O APAGADO DE DICHOS EQUIPOS.
14319
ZW4003
Out to Light (Load)
C
D
E
B
A
From Breaker Box
D. GROUND — Green/Bare
E. TRAVELER — Red/Other (only in 3-way installations)
Match these screw terminals to the wires connected to the existing switch.
6. Disconnect the wires from the existing switch. Be careful to
label wires according to the previous terminal connection.
Observe important wiring information
IMPORTANT! This switch is rated for and intended to only be used with copper wire.
Wire gauge requirements
Use 14 AWG or larger wires suitable for at least 80° C for supplying
Line (HOT), Load, Neutral, Ground and Traveler connections.
Wire strip length:
1. For attachment to screw terminals: Strip insulation 1" (25mm)
2. For attachment using the enclosure's holes: Strip insulation 5/8" (16mm)
UL specifies that the tightening torque for the screws is 14 Kgf-cm (12 lbf-in).
3. Connect the green or bare copper ground wire to the GROUND terminal.
4. Connect the black wire that goes to the fixture to the terminal marked LOAD.
5. Connect the black wire that comes from the electrical
service panel (Hot) to the terminal marked LINE.
6. Connect the white wire to the neutral terminal
(use included jumper wire if needed).
To remove and reset the device
1. Follow the instructions for your Z-Wave certified controller to remove a device
from the Z-Wave network.
2. Once the controller is ready to remove your device, press up and release the
toggle to remove it from the network.
To return your switch to factory defaults:
Quickly press ON (Up) button three (3) times then immediately press the OFF
(Down) button three (3) times.
Note: This should only be used in the event your network's primary controller is
missing or otherwise inoperable.
WARRANTY
JASCO Products warrants this product to be free from manufacturing defects for a period of
two years from the original date of consumer purchase. This warranty is limited to the repair or
replacement of this product only and does not extend to consequential or incidental damage
to other products that may be used with this product. This warranty is in lieu of all other
warranties, expressed or implied. Some states do not allow limitations on how long an implied
warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so
the above limitations may not apply to you. This warranty gives you specific rights, and you
may also have other rights which vary from state to state. Please contact Customer Service at
800-654-8483 (option 1) between 7AM – 8PM CST or via our website (www.byjasco.com) if the
unit should prove defective within the warranty period.
GARANTIE
JASCO Products garantit que ce produit est exempt de tout défaut de fabrication pour une
période de deux ans à compter de la date de l'achat original par l'acheteur. Cette garantie se
limite exclusivement à la réparation ou au remplacement de ce produit et n'est pas applicable
aux dommages indirects ou accessoires survenus sur d'autres produits utilisés avec ce
produit. Cette garantie se substitue à toute autre garantie expresse ou implicite. Certains États
ne permettent pas de restrictions quant à la durée d'une garantie implicite ou permettent
l'exclusion ou la limitation des dommages indirects et accessoires; il se peut, par conséquent,
que cette garantie ne s'applique pas dans votre cas. Cette garantie vous confère des droits
juridiques précis; vous pouvez jouir d'autres droits qui peuvent varier d'un État à l'autre.
Veuillez communiquer avec le service à la clientèle au 1-800-654-8483 (option 1) entre 7 h et
20 h (heure normale du Centre) ou par l'intermédiaire de notre site web (www.byjasco.com) si
l'appareil s'avère défaillant au cours de la période de garantie.
GARANTÍA
JASCO Products garantiza que este producto está libre de defectos de fabricación durante
un periodo de dos años a partir de la fecha original de compra por parte del consumidor. Esta
garantía se limita a la reparación o sustitución de este producto solamente y no se extiende
a daños derivados o accidentales causados a otros productos que se usen con esta unidad.
Esa garantía remplaza a todas las demás garantías expresas o implícitas. Algunos estados no
autorizan limitaciones en cuanto a la duración de una garantía implícita ni permiten la exclusión
o limitación por daños accidentales o derivados; por lo tanto, puede que las anteriores
limitaciones no apliquen en su caso. Esta garantía le da a usted derechos específicos, y
otros que usted puede tener y que varían según el estado en el que usted reside. Si la unidad
resultare defectuosa dentro del periodo de garantía, comuníquese por favor con Atención al
Cliente en el 800-654-8483 (opción 1) entre 7 y 20 h, Hora del Centro, o a través de nuestro
sitio de internet (www.byjasco.com).
JASCO Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.
SPECIFICATIONS
ZW4003
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.4/916 MHz.
Maximum Loads: 960W, incandescent, ½ HP Motor or 1800W (15A) Resistive
Range: Up to 150 ft. line of sight between the Wireless Controller and the closest Z-Wave receiver module.
Operating Temperature Range: 32-104° F (0-40° C).
For indoor use only.
Specifications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW4003
Tension : 120 V c.a., 60 Hz.
Signal (fréquence) : 908.4/916 MHz.
Charges maximales : 960 watts (incandescent), moteur de ½ HP ou résistance de 1800 W (15 A).
Portée : Distance à vue entre la télécommande et le module de réception Z-Wave le plus proche allant jusqu'à
150 pi.
Plage de températures de fonctionnement : de 32 à 104 °F (de 0 à 40 °C).
Utilisation intérieure uniquement.
En raison d'améliorations continues du produit, les spécifications peuvent faire l'objet de changements sans
préavis.
ESPECIFICACIONES:
ZW4003
Energía: 120 VCA, 60 Hz.
Señal (Frecuencia): 908.4/916 MHz.
Cargas máximas: 960 W, incandescente, ½ HP motor o 1800 W (15 A) resistiva
Alcance: Hasta 150 pies (45.72m) en línea de visibilidad directa entre el control inalámbrico y el módulo receptor
Z-Wave más cercano.
Rango de temperatura de funcionamiento: 32-104° F (0-40° C).
Para uso en espacios interiores solamente.
Especificaciones sujetas a cambio sin aviso debido a continuas mejoras del producto
Out to Light (Load)
C
D
E
B
A
From Breaker Box
NOTE: The Traveler terminal is only used for 3-way or 4-way
wiring and should remain insulated if the switch is being
installed in a 2-way system (one switch & one load).
7. Insert switch into the switch box being careful not to pinch or crush wires.
8. Secure the switch to the box using the supplied screws.
9. Mount the wallplate.
10. Reapply power to the circuit at fuse box or circuit breaker and test the system.
Basic operation
The connected light can be turned ON/OFF in two ways:
1. Manually from the front panel of the In-Wall Switch.
2. Remotely with a Z-Wave Controller.
Manual control
The front panel toggle switch allows the user to
turn ON/OFF the connected fixture.
1. To turn the connected fixture ON: Press and release up on the toggle.
2. To turn the connected fixture OFF: Press and release down on the toggle.
The Jasco Add-on switch is required for Multi-Switch 3-way or 4-way installations.
Connecting the traveler terminal of this switch to a standard, non-Jasco switch will cause
damage or result in improper function. If this switch is a part of a 3-way or 4-way multi-switch
installation, do not connect the traveler wire or apply power until Jasco Add-on switches are
correctly installed. For more information on 3-way or 4-way installations, view the manual or
quick-start guide that comes with the Jasco Add-on switch.
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave
network with other Z-Wave certified devices from other
manufacturers and/or other applications. All non-battery
operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
• This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Binary Switch Report
• Association Group 2 supports Basic Set and is controlled with the local load
• Association Group 3 supports Basic Set and is controlled by pressing the on or off button
• Each Association Group supports 5 total nodes

Publicidad

loading

Resumen de contenidos para Jasco 14319

  • Página 1 • Turn ON/OFF manually or remotely via the Z-Wave controller • Can be included in multiple Groups and Scenes • May be used in single pole installation or with up to two Jasco Add-on switches From Breaker Box in 3-way or 4-way wiring configurations •...
  • Página 2 Sortie à l’appareil Out to Light (Load) d’éclairage (charge) Sortie à l’appareil Out to Light (Load) d’éclairage (charge) Outils dont vous aurez besoin De la boîte des disjoncteurs From Breaker Box IMPORTANT! L’appareil d’éclairage commandé par l’interrupteur intelligent mural Z-Wave ne doit pas dépasser 960 W (ampoules à...
  • Página 3 Model: 14319 / ZW4003 ADVANCED OPERATION The following Advanced Operation parameters require that you have a controller that supports the advanced configuration command class. All On/All Off Depending upon your primary controller, this Z-Wave module can be set to respond to ALL ON and ALL OFF commands in up to four different ways.

Este manual también es adecuado para:

Zw4003