Symptom
Pump will not start or run
Pump starts and stops too
often
Pump will not shut off or
thermal protector turns off
Pump operates but delivers
little or no water
Gurgling sound from pump at
end of cycle
Possible Cause(s)
1. Blown fuse
2. Low line voltage
3. Defective motor
4. Defective float switch
5. Impeller bound-up
6. Float obstructed
1. Backflow of water from piping
2. Faulty float switch
3. Incoming water is draining on
sensor face
1. Defective float switch
2. Obstacle in piping
3. Float obstructed
4. Low line voltage
5. Too many appliances on circuit
6. Dirty Solid-State Water Sensor
7. Incoming water is draining on
sensor face
1. Low line voltage
2. Plugged impeller
3. Check valve installed backwards
4. Pump airlocked
1. Air injested into pump
2. Time required for pumping is less
than 4 seconds
BWST, BWSF and BWSCAP Series
Corrective Action
1. If blown, replace with proper sized fuse or reset
breaker
2. If voltage is under 108 volts, check wiring size
3. Replace pump
4. Replace float switch
5. If impeller will not turn, remove housing and
remove blockage
6. Make sure float move freely up and down
1. Install or replace check valve (Blue Angel check
valve kit #66005-BLA)
2. Replace float switch
3. Position pump switch away from the inlet so
switch is clear from incoming water (See Figure
3).
1. Replace float switch
2. Remove pump and clean pump and piping
3. Make sure float move freely up and down
4. If voltage is under 108 volts, check wiring size
5. Install pump on dedicated circuit.
IMPORTANT: Do not use extension cord to power
pump.
6. Clean sensor face (see Figure 5)
7. Position pump switch away from the inlet so
switch is clear from incoming water (see Figure
3)
1. If voltage is under 108 volts, check wiring size
2. Clean out impeller
3. Reverse position of check valve
4. Drill 1/8 inch hole in discharge line between
pump and check valve
1. Wipe off surface of sensor (see Figure 5)
2. Additional run time will not damage pump