Essick Air H12 Serie Manual De Uso Y Cuidado Del Propietario página 7

Ocultar thumbs Ver también para H12 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Trouble
Unit does not operate on any
speed setting
Motor does not Turn On.
Water not draining into
reservoir
Not enough humidity.
Too much humidity.
(condensation becomes heavy
on fold surfaces in room)
Water leak
Odor
Probable Cause
No power to unit.
Unit has run out of water – fan
will not operate without water is
present.
Refill switch operation/improper
positioning of float assy.
Check motor/fan operation.
Water bottle incorrectly
positioned.
If unit has overheated, motor
temp-sensing fuse may have
tripped.
Wick is old and ineffective.
Humidistat is not set high
enough
Humidistat is set too high.
Water reservoir may have been
overfilled. Or bottle may be
releasing too much water.
Bacteria may be present.
7
Remedy
Ensure polarized plug is fully inserted
in wall outlet.
Refill water bottle.
Ensure float assembly is correctly
positioned as described in
"Important Filling Instructions", page 4.
CAUTION: Do not touch the fan
when accomplishing this test, as
the motor may turn on.
To test the motor, turn unit ON and
turn all dials fully ON.
Turn the chassis over and insert
finger into tab where float rod is
supposed to go. If fan turns on, the
fan and motor are working
correctly.
Unplug unit. Remove water bottle
and reassemble without water
bottle. Turn on and see if fan
comes on. If so, replace water
bottle and continue operation.
Take unit to authorized service
station. DO NOT ATTEMPT
electrical repairs yourself.
Replace wick when clogged or
hardened with minerals.
Increase humidity setting on control
panel.
Reduce humidistat setting or
increase room temperature.
DO NOT OVERFILL bottle and
reservoir. DO NOT puncture bottle
to make bottle drain faster.
Clean and disinfect cabinet following
Care and Maintenance instructions.
Add Essick Bacteria Treatment
According to instructions on the
bottle.
It may be necessary to replace the
wick if odor persists.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

H12300hbH12300ltH12300oakH12 400hbH12 400oakH12 400burl

Tabla de contenido