Ce Declaration Of Conformity - GBD SC130 Instrucciones Para La Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SC130
COMPLETE CANCELLATION OF TRANSMITTERS MEMORY: Push the button P1 (the led blinks, then turns on)
and keep it pushed as long as the led will blink again and turn off (10s). When you release the button, the led turns on
again, indicating that the system is ready to learn a new transmitter.
LEARNING OF TRANSMITTERS WITHOUT ACCEDING TO THE CONTROL UNIT (ROLLING
TRANSMITTERS): Push the buttons UP and DOWN of the terminal board at the same time for 1 s or the buttons
1 and 2 of a transmitter already stored at the same time for 2 s. The control unit will enter in LEARNING and it will be
possible to follow the usual procedure to store the new transmitters.
PEDESTRIAN MANOEUVRE
With the 2nd button learned by the transmitter or DOWN from terminal board, the gate opens for 7 s, a START makes
open all and denies the pedestrian.
DISPOSAL
GI.BI.DI. advises recycling the plastic components and to dispose of them at special authorised
centres for electronic components thus protecting the environment from polluting substances.
The manufacturer:
GI.BI.DI. S.r.l.
Via Abetone Brennero, 177/B,
46025 Poggio Rusco (MN) ITALY
declares that the product:
ELECTRONIC CONTROL UNIT SC130
is in conformity with the following EEC Directives:
• LVD Directive 2006/95/CE and subsequent amendments
• EMC Directive 2004/108/CE and subsequent amendments
and that the following harmonised standards have been applied:
• EN60335-1
• EN 61000-6-2, EN 61000-6-3
Date 15/06/2017

CE Declaration of conformity

The Legal Representative
Michele Prandi
13