The Com-Pak™ Bath Heater
OWNER'S GUIDE FOR MULTI-VOLT MODELS
The Com-Pak™ Bath Heater
10" Width
Tools Required:
Utility Knife
Phillips Screwdriver
4 1
Straight Screwdriver
3 Insulated Wire Connectors
Wire Strippers
1 Strain Relief Connector
WARNING
Turn the electrical power off at the electrical panel
board (circuit breaker or fuse box) and lock or tag
the panel board door to prevent someone from
turning on power while you are working on the
heater. Failure to do so could result in serious
electrical shock, burns, or possible death.
1. Read all instructions before using this heater.
2. Read all information labels. Verify that the electrical
supply wires are the same voltage as the heater.
3. All electrical work and materials must comply with the
National Electric Code (NEC), the Occupational Safety and
Health Act (OSHA), and all state and local codes.
4. Connect the grounding pigtail (copper wire) provided in
the wall can to the supply ground wire.
5. If you need to install a new circuit or need additional
wiring information, consult a qualified electrician.
6. Protect electrical supply from kinks, sharp objects, oil,
grease, hot surfaces or chemicals.
7.
WARNING
Overheating or fire may occur. DO NOT install the heater in
a floor, in the ceiling, below a towel bar, behind a door, or
anywhere the air discharge may be blocked in any manner.
8.
WARNING
Fire or explosion may occur. DO NOT install heater in any
area where combustible vapors, gases, liquids, or
360-693-2505 Fax: 360-694-8668 P.O. Box 1675 Vancouver, WA 98668-1675
1/2" Depth
/
" Wood Screws
1
2
IMPORTANT INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Features & Benefits
■ Primary and secondary thermal
safeguards
• High temperature manual reset
• Over temperature one-time thermal device
■ Commercial grade steel element - painted to
resist rusting
■ Built-in controls
- Single pole thermostat
- 60 minute timer
■ Powder coat paint process eliminates
sharp cutting edges
■ Three year extended warranty on
element and motor
■ Factory tested
■ Multi-Volt configurations
120 or 240 Volt AC (1000 Watts)
*Factory set at 240-Volts
Models:
CBC103TW or CB103T The Com-Pak Bathroom Heater
excessive lint or dust are present.
9.
WARNING
DO NOT install where heater is likely to get wet.
10.
WARNING
Heater must be connected to a GFCI protected branch circuit.
11.
WARNING
Burn Hazard. This heater is hot when in use. To avoid burns,
do not let bare skin touch hot surfaces. Use extreme caution
when any heater is used by or near children or invalids.
12.
WARNING
Risk of Electrical Shock. DO NOT install the heater directly
above bathtub or sink. DO NOT install in shower stall area
(Manufacturer recommends a minimum 2 foot clearance).
13.
WARNING
Risk of Electrical Shock. Connect grounding lead
to grounding wire provided. Keep all foreign objects
out of heater.
14.
WARNING
Risk of Electrical Shock. Never place a switch where it can
be reached from the tub or shower enclosure.
15.
WARNING
Risk of Fire. Do not block heater. Heater must be kept clear
of all obstructions: a minimum of 3 feet in front, 6 inches
above and on both sides. Heaters must be kept clean of lint,
dirt and debris. (See Maintenance Instructions).