GENERAL INFORMATION

A.
Your portable gas-fired infra-red heater comes fully assembled
and is tested at the factory for proper gas and input as stated
on the nameplate.
B.
Each heater is equipped with a 100% safety shutoff, push
button valve which will automatically stop the flow of gas in
the event the heater fails to operate for any reason. A tip over
switch and an excess flow check are also standard on the
model MH18CH.
C.
Before proceeding with this installation, be sure to inspect
for damages. The freight company must be notified of any
damages and request that an inspection be made. Enerco
Technical Products will send replacements for damaged parts
only after receiving a signed inspection report to prove the
liability of the freight company.

FOR SAFE OPERATION

1.
READ THESE INSTRUCTIONS CAREFULLY. Read and
adhere to these instructions. DO NOT allow anyone
who has not read these instructions to assemble, light,
adjust or operate this heater.
2.
LP-Gas IS HIGHLY FLAMMABLE. In the event of a leak,
LP-Gas will accumulate and the possibility of a fire is present.
LP-Gas is scented and its strong odor is readily detectable.
Never strike a match, bring any flame or create an electric
spark in an enclosure when you smell LP-Gas. Ventilate the
area thoroughly, move the heater outside, and correct the
source of the leak before attempting to light any appliance.
3.
Keep children and pets away from the heater.
4.
Check the heater thoroughly for damage. DO NOT operate a
damaged heater.
5.
DO NOT modify the heater or operate a heater which has
been modified from its original condition.
6.
Use only propane gas.
7.
Use only VAPOR WITHDRAWAL propane supply. If there is
any question about vapor withdrawal, ask your propane
dealer.
8.
Mount the propane cylinders vertically (shutoff valve up).
Secure the 20# propane tank inside the cabinet to protect it
from damage.
9.
DO NOT direct the heater toward another propane tank
within 20 feet of the heater.
10. IMPORTANT Use only the hose and regulator assembly
provided with the heater. Replace only with factory approved
components..
11. This heater is primarily intended for temporarily heating of
buildings under construction, alteration or repair. Area must
be well ventilated. Never use in an occupied dwelling.
12. If at any time gas odor is detected, IMMEDIATELY
DISCONTINUE operation until the source of gas has been
located and corrected. Read enclosed Odor fade and Propane
Sheet for additional information about detecting propane
leaks.
13. Install the heater such that it is not directly exposed to water
spray, rain and/or dripping water.
E3
Portable Propane Cabinet Heater
14. Maintain minimum clearance from combustible material (like
paper). Page 2. Never place flammable items on the heater.
15. Due to the high surface and exhaust temperatures, adults and
children must observe clearances to avoid burns or clothing
ignition.
16. Operate only on a stable, level surface.
17. DO NOT connect to an unregulated propane source.
18. DO NOT move, handle or service while hot or burning.
19. DO NOT use heater on finished floors.
20. Use only in accordance with local codes or, in the absence of
local codes, with the Standard for the Storage and Handling
of Liquefied Petroleum Gases ANSI/NfPA 58 and CSA B149.1,
Natural Gas and Propane Installation Code.

INSTALLATION INSTRUCTIONS

GENERAL
for the U.S. and/or Canada, the installation of this appliance must
comply with local and/or Provincial codes or, in the absence of
these codes,
With the (U.S.) National fuel Gas Code, ANSI Z223.1 – Latest
Edition, AND with the (U.S.) Standard for the Storage and
Handling of Liquified Petroleum Gases, ANSI/NfPA 58, OR
With the current (Canadian) CAN/CGA B149.1 AND B149.2
INSTALLATION CODES.
This heater (including hose and regulator assembly) must be
inspected before each use and at least annually by a qualified
service person. If the hose for Model MH18CH shows evidence
of excessive abrasion or wear, or if the hose is cut, it must
be replaced prior to the heater being put into operation. The
replacement hose assembly shall be that specified by the
manufacturer. See the parts list.
The minimum ambient temperature rating for this heater is 20
degrees f.
This heater incorporates a "Tip Over" switch which automatically
shuts off the burner in the event of tipping. Ensure that this switch
is in the vertical position and is secured with the screws provided.
DO NOT operate this heater with the LP-gas supply cylinder
in any other than the upright position.

LOCATION

Although this heater incorporates a "tip over" switch, the heater
and LP-Gas supply cylinder must be located on a hard, flat,
level surface to minimize the risk of accidental tipping. The LP
Gas supply cylinder should be adequately restrained to prevent
accidental tipping. DO NOT OPERATE this heater with the
supply cylinder in any other than the upright position.
This appliance must be installed only in locations where the
potential for physical damage to the appliance (i.e., due to
physical contact) is reduced to a minimum.
Use of this heater in a draft/windy area may decrease its
efficiency. If possible, operate the unit in a draft free area or turn
the face of the heater away from the draft.