You will need:
A water heater set to deliver 120° F (49° C) water to the washer.
A grounded electrical outlet located within 6 ft. (1.8 m) of where the power cord is attached to the back of
the washer. Refer to "Grounding Instructions" on page 4.
Hot and cold water faucets located within 4 ft. (1.2 m) of the hot and cold water fill valves, and water
pressure of 20-100 psi (137.9 - 689.6 kPa) .
A level floor with a maximum slope of 1" (25 mm) under entire washer. DO NOT install the washer on soft
floor surfaces, such as carpets or surfaces with foam backing.
A sturdy and solid floor to support the washer with a total weight (water and load) of 200lbs.
DO NOT operate your washer in temperatures below 32° F (0° C) . Some water can remain in the washer and
can cause damage in low temperatures.

INSTALLATION CLEARANCES

The location must be large enough to allow the washer door to be fully opened.
Additional spacing should be considered for ease of installation and servicing. The door opens more than 90°
and it is NOT reversible.
Additional clearances might be required for wall, door and floor moldings.
Additional spacing of 1" (25mm) on all sides of the washer is recommended to reduce noise transfer.
Companion appliance spacing should also be considered.
RECOMMENDED SPACING FOR UNDER-COUNTER INSTALLATION
2.0" (50 mm)
33.5"
(850 mm)
1.0" (25 mm)
23.5" (595 mm)
12
Figure 4
1.0" (25 mm)