SYMPTOM
OlyBond500 does not flow
from gun
Machine pumps unequal
amounts of materials 1 and 2
OlyBond500 does not foam up
Material foams up, but has
no holding power
Motor turns but pump does
not supply material
Motor doesn't turn
PaceCart 2 Troubleshooting
REPAIR SUGGESTION
Check to see if gun, whips or hoses are clogged. Clear any clogs and repeat
Steps 2, 4, 5 and 6 of operating instructions.
OR: Make sure pumps are working.
Flow might be disrupted by clog. Make sure the materials are at the correct
application temperature.
OR: Check hose for even flow.
OR: Clean gun.
OR: Check part 1 pump for blockage.
Gun may not be delivering equal amounts of material (from boxes 1 & 2),
thereby preventing chemical reaction. Check for clogs in hoses or gun.
OR: Check boxes for inadequate material levels.
Foam may be off ratio. Check for equal flow of Part 1 & Part 2.
OR: Material may have been frozen. Dispose of it and replace with fresh material.
Pump may be clogged or broken. Call 800 . 633 . 3800 for assistance.
Make sure on/off switch is in "on" position.
OR: Make sure breaker switch is on.
OR: Pressure switch may be activated. Open valves to relieve pressure in hoses.
If none of these remedy the situation, check power source. Turn off PaceCart 2
immediately as insufficient power will damage the motor.
Be sure your power cord is no longer than 100 feet.
OR: Be sure your power source is delivering power at 110-125v, 15 amp.
OR: Check for competing equipment on the same line.
OR: Pump may be frozen. With motor off, insert flathead screwdriver as shown below
and turn clockwise to "unlock" pump. See illustration below.
UNFREEZING PUMP
O M G R O O F I N G P R O D U C T S
8 0 0 . 6 3 3 . 3 8 0 0
W W W . O L Y F A S T . C O M
6