S-Class Professional:
430 mm
± 100 mm
430 mm
± 100 mm
Connecting the modules with the substructure:
There are several methods to connect the modules
to substructure: by clamping the modules from the
front (examples A and B) or by bolting the modules
from the back (example C) using the provided at-
tachment holes .
Use a torque wrench for installation . The re-
quired tightening torque for the above samples
is 14 .8 lb ft (20 Nm) . Use M6 bolts made of V2A .
Only use the provided holes for installation . If any
further holes are drilled, the warranty will no longer
apply. Always use appropriate corrosion-proof fix-
ing materials for installation .
Example A: Clamping plate
Example B: Clamping wing
Example C: Direct bolting
23