Troubleshooting
No Sound
Check that the receiver and transmitters are both turned on, and that the transmit-
ters are not muted. Verify that the 500IR battery is charged, or else that the 500IR is
plugged into an AC supply with the correct power adapter. Ensure that the recom-
mended NiMH rechargeable batteries are installed in the 501TI, observing the cor-
rect polarity. Verify that the 500IR receiver is receiving signal (indicated by a green
LED). Check or replace transmitter microphone.
No IR Signal
Check that the transmitters and receivers are set to matching channels. Check or re-
place batteries. Check that the transmitter is ON. Remove obstructions from the line
of transmission. Ensure the IRS-20 remote sensors are deployed correctly.
Dead Batteries
Ensure that the recommended NiMH rechargeable batteries are installed in the
transmitter, observing the correct polarity. Make sure the microphone is making con-
tact in the pocket of the charging cradle, and that the charger is in turn connected to
the correct power adapter.
Weak Sound
Check and adjust volume setting. Adjust microphone position. Check or replace mi-
crophone. Check that the correct power adapter is connected to the receiver.
Noise or Distortion
If using two transmitters, check that they are set to different channels. Check for
possible sources of interference, especially direct sunlight. Check the integrity of the
microphone, its cord and its plug. Clean microphone plug pin with swabbing alcohol
or other solvent to maintain noise-free connection.
Flashing Charging Cradle Light
The transmitter is refusing to charge. Ensure that the recommended NiMH recharge-
able batteries are installed in the transmitter, observing the correct polarity.
Feedback
Check and adjust volume settings. Ensure that the microphone is positioned cor-
rectly. Avoid approaching too close to the receiver with the transmitter turned on.
Intermittency
Check the integrity of the microphone, its cord and its plug. Replace the microphone
if necessary. Ensure IR sensors are deployed efficiently and that cables are connected
to the remote sensors (if used). Remove any obstructions between transmitter(s) and
sensors.