Gas Requirements; High Altitude - Forza FRT304GN Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Gas Requirements

QUALIFIED SERVICE MAN OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS
SUPPLY CONNECTION.

High Altitude

For altitudes above 2,000 feet (610 m) above sea level, adjustments can be made with the instructions in the manual. If flame
performance is satisfactory, will not be required regulation. It is required that a Certified Professional make the high altitude
adjustments during installation.
Gas line must not come in contact with any components inside back cover of
the range.
If the line pressure supplying the appliance pressure regulator exceeds 14
inches W.C. (any gas), an external regulator must be installed in the gas line
ahead of the appliance regulator to reduce the pressure to no more than 14
inches W.C. Failure to do this can result in malfunction and damage to the
appliance.
The appliance must be isolated from the gas supply piping system by closing
its individual manual shut-off valve during any pressure testing of the gas
supply piping system at test pressures exceeds, equal to or less than ½ psig
(3.5kPa.) and damage to the appliance.
18

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Frt366gn

Tabla de contenido