Cable Connections

Connecting External Power

NOTE: This procedure is not required if Power over Ethernet (PoE) is
used.
If PoE is not available, the dome camera can be powered with 24 VAC
or 24 VDC through the removable power connector:
1.
Remove as much insulation as required to splice the
supplied power connector to the power adapter wires (not
included).
Do not nick or damage the wires.
2.
Remove the dummy plug from the power receptacle on the
device.
See the diagram on page 2 for the location of the external
power receptacle.
3.
Attach the power connector to the receptacle on the
camera.
Table: Power Connector Pin Details
Pin
Wire Color
1
Brown
2
Not used
3
Blue
Warning — This product is intended to be supplied by a UL
Listed Power Unit marked "Class 2" or "LPS" or "Limited
Power Source" with output rated 24 VAC +/- 10%, 55 VA
min. or 24 VDC +/- 10%, 44 W min.
10
Function
Power, accepts either polarity
Not used
Power, accepts either polarity