2D
Parallel Only
Timeout/EN81-20
Timeout Period
Cdn TMO Period
Sleep
3D
3D Enable
3D Mode
Sensitivity
Timeout Count
Second Relay
Copy Main
EN81-20 Mode
Canadian
Disabled
Audio
Beeper
Speech
Speech Volume
Speaker
Panachrome
Off
or deactivate a further 186 diagonal beams. Choose to have
On
parallel beams only ON or OFF.
Off
This enables/disables 2D timeout for up to 5 non-adjacent
infra-red diodes.
On
Beam timeout time (10 to 360s)
Canadian timeout time setting (not enabled)
Off
Turn sleep mode ON or OFF. Default OFF.
On
Off
Enable/disable 3D detection. Default OFF for 2D only
detectors (G2510 or G2540) and has no effect.
On
See Section 7 for more details
3D activates when the doors are closing.
On at Closing
3D activates when the doors are approx. 800mm apart.
On at 800mm
3D always on with no 3D timeout.
On Always
3D always on with 10s 3D timeout.
On (10s)
3D always on with 20s 3D timeout.
On (20s)
High
3D sensitivity settings. Choose according to installation. If false
Intermediate
triggering on High then choose a lower sensitivity.
Low
Counts the 3D triggers (2 to 10) and disables 3D once this count
is reached. Note: resets with a 2D trigger.
Relay 2 mimics main relay (relay 1).
Relay 2 activates when EN81-20 conditions are not met.
This can be that a diode(s) has timed out which means the
50mm target detection is now not met, or a system fault has
developed.
Canadian timeout. If a trigger is on for the timeout period (Cdn
TMO) then the relay will activate.
Relay 2 disabled.
Beeper off.
Off
Beeper active on a trigger.
Beep On
Beeper active when the doors are closing.and triggered
Beep Closing
Speech output off.
Off
Speech output on.
On
Speech volume (0 to 9). Note: 0 volume is lowest setting and
not equivalent to OFF.
Enable internal speaker.
Internal
Enable external and disable internal speaker.
External
has 48 parallel beams and the option to activate
+