Setting force value
The recommended setting force is dependent on the combination of information coming from the
insert parameters.
Insert parameters
Force
Maximum
Setting effort range
= Force to obtain
a good setting
Minimum
Stroke in
maximum thickness
Stroke in
minimum thickness
Technical features
Setting force (min - max) (kN)
Setting capacity
Maximum stroke
Weight of the tool
Weight of the battery (2,6Ah)
Battery
Environmental limitations of use
Vibration
IP degree of protection
Noise emission
32
C1: setting
C2: setting
in max
in min
thickness
thickness
Tolerance
Tolerance
( * > 18kN with appropriate accessory)
(*M10 with appropriate accessory set)
Sound pressure level, LpA : 71.1 dB(A)
Sound power level, LwA : 82.1 dB(A)
C1
Maximum thickness (C1)
C2
Stroke
Minimum thickness (C2)
3.00 –> 22.00*
Insert M3 to M10*
Stud M4 to M8
7.0 mm
2.1 kg
0.3 kg
Li-Ion / 14.4 V / 2.6 Ah
5°C - 40°C
Vibration amplitude: 0.672 m/s²
20