1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including those that refer to national and
European standards, shall be complied with when installing the
product.
Instructions for mounting, installation and use are enclosed with
the product. Prior to using the product the installation must be
inspected by a qualified person.
A product data label in heat resistant material can be found on the
heat shield at the back of the product. This contains information
about identification and documentation for the product.
2.0 Technical data
Material:
Finish:
Fuel:
Log length, max.:
Operating range:
Flue outlet:
Flue pipe dimension:
Weight:
Options extras:
Dimensions, distances:
Technical data according to EN 13229
Nominal heat output:
Flue gas mass flow:
Recommended chimney draught:
Efficiency:
CO emission (13% O
):
2
Flue gas temperature:
Operational type:
Cast iron
Black or grey varnish
Wood
40 cm
2,6 - 7,8 kW
Top
Ø150 mm, 177 cm
cross section
2
99 kg
Fire screen, Ash solution
See fig. 1
6,0 kW
5,8 g/s
12 Pa
75%@6,8kW
0,16%
342
C
o
Intermittent