Troubleshooting (cont.)
Symptoms
3.
Whirlpool stops by itself.
4.
Noisy operation.
5.
Heater does not operate.
Kohler Co.
Probable Causes
A. GFCI or RCD trips.
B. Suction is blocked.
C. Jets are blocked.
D. Motor overheated and
protectoin device activated.
A. Pump banding straps have not
been cut. (models with wooden
support blocks only)
B. Dry or dislodged jet O-ring
(squeal).
A. No power to heater.
B. Water temperature exceeds
104°F (40°C).
C. Heater does not work.
7
Recommended Action
A. Identify source of fault and correct.
If problem persists, refer to
installler/dealer.
B. Remove obstruction.
C. Remove blockage.
D. Check for blockage at motor vents.
Remove bloackage and allow motor
to cool.
Check for suction blockage.
Remove blockage and allow motor
to cool.
Check for jet blockage. Remove
bloackage and allow motor to cool.
A. Cut pump banding straps with tin
snips.
B. Remove jet, replace and lubricate
O-ring, and reinstall jet.
A. Set/Reset GFCI or RCD breaker.
B. Allow water to cool; heater will
re-engage.
C. Replace heater. Refer to
installer/dealer.