If it is not getting any better, first of all lower the water level in the skimmer by opening the control
flow. Furthermore, reduce the length of the hose (see air bubbles), use neck extension.
In new set-up aquaria, there is usually no reasonable skimming. The skimmer produces
large quantities of wet foam. This is normal and can be adjusted with the controller until
the foam cup is no longer full.
Dry foam
Not enough or too dry foam could be an indication that the needle wheel or air injection nozzle is
dirty. A thorough cleaning is recommended. Remove the pressure fitting from the pump. If it's not a
problem of cleaning, increase water level inside the skimmer by the water level controller. Remove
neck extension.
7. Maintenance
The collection cup should be cleaned regularly (daily or weekly, depending on organic load). The
reaction pipe of the skimmer needs to be cleaned only occasionally. The venturi pump should also be
removed and cleaned regularly so there is no negative impact on the air output. The pump has to be
removed and the complete pump housing and needle wheel flushed with clean water. The same
procedure should be undertaken with the air injection nozzle.
8. Warranty
Should any defect in material or workmanship be found within 12 months of the date of purchase AB
Aqua Medic GmbH undertakes to repair or, at our option, replace the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid. The
warranty term is not applicable on the all consumable products.
Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer's
name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty
may not apply if any model or production number has been altered, deleted or removed,
unauthorised persons or organisations have executed repairs, modifications or alterations, or
damage is caused by accident, misuse or neglect. We regret we are unable to accept any liability for
any consequential loss. Please note that the product is not defective under the terms of this
warranty where the product, or any of its component parts, was not originally designed and / or
manufactured for the market in which it is used. These statements do not affect your statutory rights
as a customer.
If your AB Aqua Medic GmbH product does not appear to be working correctly or appears to be
defective please contact your dealer in the first instance. Before calling your dealer please ensure
you have read and understood the operating instructions. If you have any questions your dealer
cannot answer please contact us.
Our policy is one of continual technical improvement and we reserve the right to modify and adjust
the specification of our products without prior notification.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
- Technical changes reserved – 10/2015