Manuale d'uso ed installazione – Cleaner5-M202SV5
DAMAGE TO THE MACHINE
ATTENTION! In case of bad working, switch immediately the machine off and contact the servicing;
show the present handbook to the operator who must execute the repairing.
Some examples of verifiable damages and the relative remedies are listed here below.
THE STEAM DOES NOT COME OUT EVEN IF THE BOILER IS IN PRESSION
A) Gun connection switch is disconnected:
-- Press the switch (6).
B) The handwheel for the steam adjusting (3) is closed:
-- Unscrew this handwheel in counterclockwise way.
C) The cable of the gun is damaged:
-- Replace the cable checking the connections on the clamp.
D) The coil of the electrovalve is burned (2):
-- Replace the coil and check the working of the valve.
E) The push-button of the gun is defected:
-- Replace the push-button checking the connexions.
THE BOILER DOES NOT GO IN PRESSION EVEN IF THE GENERAL SWITCH (7) IS
CONNECTED
A) There is no water inside the boiler:
-- Switch the machine off, make sure that there is no pression, unscrew the plug and execute the filling.
B) The element is burned or it does not work properly:
-- Check the element and replace it if necessary.
C) The pressure switch does not work properly:
-- Check the tube of the pressure switch, which must be perfectly free and replace the pressure switch if
necessary.
STEAM COMES OUT FROM THE SECURITY VALVE
A) The gasket of the valve is hardened or cracked:
-- Replace the gasket or the security valve (each 2 years).
B) The pression is too high:
-- Check the pressure switch and the safety thermostat (we suggest to apply to a specialized center).
C) The security valve is damaged:
-- Because of the importance of this component we suggest to replace it without hesitation.
NOTE
In course of consultation of the drawing of the esploded view, it is possible to obtain the code number by
looking for the reference number (placed near the drawn component) and consulting the column "NR.
LEG." of the list.
The gun is contemplate as accessory, so is out of guarantee.
del 08-07-2015- C:\Documenti\MANUALI D'ISTRUZIONI E DOC\SETTORE
DENTALE\CLEANER\CLEANER 5\MANUALI D'ISTRUZIONE\CLEANER 5 - CLEANER 5
+PISTOLA 230V\Cleaner5 M202SV5 R01.doc
In case of failure of the level glass, descaling the
junction (located at the base level), by unscrewing
the screw as shown in figure.
Pag. 8 di 23