Safety; Specifications - Facom NU-709/95 Guía De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
G B

Safety

Never use the Multitester on direct or alternating current circuits with
an effective voltage over 600 V, or at an effective voltage of ± 600 V
compared to the earth voltage.
Always check the condition of the batteries before using your Multitester 709.
Never carry out resistance tests on a circuit under tension.
Never open the Multitester case without first disconnecting it from any power source.
Never connect the Multitester to the circuit to be tested if the case is not properly
closed.

Specifications

Dimensions
: 170 x 65 x 30 mm.
Weight
: 200 g including batteries.
2 batteries
: 1.5 volt
Endurance
: 10,000 tests of 10 seconds each using R6 batteries.
Consumption
: < 5 mA used as voltmeter.
Capacity
Voltmeter
: 600 volt maximum in AC and in DC.
Ohmmeter
: 2 kΩ maximum.
Stops automatically when contacts are no longer connected.
NB: Operates automatically when contacts are connected to electrical tension.
Operating temperature
Storage temperature
Relative humidity in use
Relative humidity in storage
Double isolation
Isolation protection indicator
Radiated fields
Free fall
Vibration
Shock
Electric shock
Electrostatic discharge
Surges
Automatic lighting
Anti-slip protector
Winding groove for lead
2 captive screws enabling the lower half of the case to be removed to change the
batteries.
Housing for removable contact.
Slide for engaging and protecting black contact.
Beep for continuity test (R ≤ 500 Ω ± 50Ω )
Comes with a black lead
red contact, an instruction booklet, a one-year certificate of guarantee and 2 1.5 volt
R6 batteries
(not fitted)
(R6 or LR6 type).
20,000 tests of 10 seconds each using LR6 batteries.
< 20 mA used as ohmmeter with audible signal.
< 50 mA with lighting.
:
:
:
:
: Installation category III - contamination degree 2
:
:
:
:
:
:
:
:
: Over 50 lux.
(length 1.40 m)
.
-10° to +55° C
-40° to +70° C
10% to 90% RH
5% to 95% RH
(in accordance with IEC standard 1010-1).
IP 54
(in accordance with IEC 529).
3 V/m
(in accordance with IEC 801-3).
1 m
(in accordance with IEC 1010).
0.75 mm
(in accordance with IEC 68.2.6).
0.5 Joule
(in accordance with IEC 68.2.27).
3 kV
(in accordance with IEC 801-5).
4 kV class 2
(in accordance with IEC 801-2).
2 kV
(in accordance with IEC 801-4).
with a non-removable contact, a removable
9

Publicidad

Tabla de contenido
loading

Tabla de contenido