3. DESCRIPTION

3.1. J1 PLUG
Insert the receiver card in the block connector J1 (Fig. 2) as
indicated in Fig. 3.
For programming the receiver card, consult the individual
instructions.
Fig. 3
3.2. TERMINAL BOARD J2 (low voltage)
1 = OPEN A (N.O.) – Total opening
This is any pulse generator with N.O. contact which, when
activated, produces a gate opening movement. In A, E and S
logics, it commands both opening and closing.
To install several Open A devices, connect N.O. contacts in
parallel.
2 = OPEN B (N.O.) – Opening for pedestrians / Closing
This is any pulse generator with N.O. contact which, when
activated in logics A, E and S, produces a gate opening
movement for pedestrians. In B and C logics, it commands a
closing movement.
To install several Open B devices, connect N.O. contacts in
parallel.
3 = STOP command (N.C.)
This is any device (e.g. a push-button) which, by opening a
contact, stops gate movement.
To install several stop devices, connect the N.C. contacts in
series.
! ! ! ! ! If Stop devices are not connected, link the input to the
common contact (terminal 5) via a jumper.
4 = FSW closing safety devices contact (N.C.)
Safety devices are all devices (photocells, sensitive edges,
magnetic coils) with N.C. contact, which, if there is an obstacle
in the area they protect, operate to interrupt gate movement.
The purpose of the closing safety devices is to protect the gate
movement area during closing.
If the safety devices are tripped during closure, gate movement
is reversed, whereas they have no effect during opening. If used
when the gate is open or pausing, closing safety devices prevent
its closing.
To install several safety devices, connect the N.C. contacts in
series.
! ! ! ! ! If closing safety devices are not connected, link this input to
the common contact (terminal 5) via a jumper.
5 = Common contact for commands
6 = Negative of accessories power supply
7 = 24 Vdc (+) power supply for accessories
Max load of accessories is 500 mA. To calculate absorption values,
refer to the instructions for individual accessories.
9 = Warning light output (24 Vac)
The maximum load of the warning light is 5 W. For instructions on
operation of the warning light, consult microswitch programming.
! ! ! ! ! If you cut out jumper LK1, you obtain a voltage free contact
between terminals 8 and 9 (see fig. 6).
COMPLETE LK1
10 = 24 Vdc (+) power supply for inductive limit switch
11 = Limit switch common contact
12 = Opening limit switch (N.O.)
13 = Closing limit switch (N.O.)
3.3. TERMINAL BOARD J3 (high voltage)
Terminal board for connecting flashlight (max 60W).
3.4. TERMINAL BOARD J4 (high voltage)
Terminal board for connection of motor.
3.5. TERMINAL BOARD J5 (high voltage)
Terminal board for supplying power of 400V 3ph + Neutral - 50 Hz
(see fig.2) or 230V 3ph - 50 Hz (see fig.5).
3.6. SIGNALLING LEDS
6 LEDs are fitted on the card, indicating status of terminal board
inputs:
Led lighted = contact closed
Led off
TABLE 3: STATUS OF LEDS
E L
D
I L
G
H
E T
D
O
P
E
N
A
c
o
m
m
a
n
d
a
t c
v i
e
O
P
E
N
B
c
o
m
m
a
n
d
a
t c
v i
e
T S
O
P
c
o
m
m
a
n
d
n i
a
t c
v i
s
a
e f
y t
d
e
v
c i
e
s
n
t o
S F
W
o
p
r e
t a
n i
g
l c
s o
n i
g
i l
m
t i
e s
n
o s
f r
F
C
C
F
C
A
o
p
e
n
n i
g
i l
m
t i
s
e
n
s
NB.: The status of the LEDs while the gate is at rest are shown in
bold.
8
INTERRUPTED LK1
(Free contact)
= contact open
O
F F
c
o
m
m
a
n
d
n i
a
t c
v i
e
c
o
m
m
a
n
d
n i
a
t c
v i
e
e
c
o
m
m
a
n
d
a
t c
v i
e
s
a
e f
y t
d
e
v
c i
s e
o
p
r e
c
o l
s
n i
g
i l
m
t i
s
e
n
s
r o
e r
e
e
n
g
a
g
e
d
o
p
e
n
n i
g
i l
m
t i
e s
s n
r o
o
f r
e r
e
e
n
g
a
g
e
d
Fig. 4