01877
electronic multi-voltage power supply 230 v~ 50 Hz for dimmerable RgB led
lamps 12-24 v , adjustable with By-me devices. selv output.
CHaRaCteRistiCs
• Rated output voltage: 12-24V
± 10%
• Suited for SELV RGB LED lamps (art. 02663) and strips: 12-24 V
• Rated supply voltage mains: 230 V~ 50 Hz
• Rated supply voltage Busbar: 29 V
• Absorption at 230 V~:
- 125 mA (output 12 V
20 W)
- 145 mA (output 24 V
24 W)
• Absorption from BUS 29 V: 10 mA
• Fuse with high breaking capacity type 1 A incorporated
• Terminals:
- 2 for mains supply (L phase, N neutral)
- 4 for LED output module (+, R-, G-, B-)
- 2 for TP Busbar (+,-)
• Possible functions:
- Switching on, off and dimmering
- Changing absolute colour
- Actuating/saving scenarios
- FADING SHOW operation
- "Ramp" operation
- Switch-off delay and warning function
- Hue/saturation/brightness adjustment
• Operating temperature: -5°C - +45°C (indoor)
• Appliances of class II
• Jumpers for selecting the output voltage
• maximum overall output current:
- 1.7 A at 12 V
- 1 A at 24 V
• maximum overall load:
- 20 W (12 V output
)
- 24 W (24 V output
)
• PfC active:
- Power factor = 0.92 (12 V
, 20 W)
- Power factor = 0.90 (24 V
, 24 W)
• Max. dissipated power: 6 W at 12 to 24 V
• Efficiency η at 230 V~:
- 80% (12 V
, 20 W)
- 84% (24 V
, 24 W)
• Consumption on standby: < 0.5 W
• Max number of power supplies
- with miniature circuit breaker C10: max 7
- with miniature circuit breaker C16: max 12
• Power supply to incorporate IP20 for indoor use
• Galvanic isolation between primary and secondary: 4 kVrms
• Adjustable power supply with By-me devices
• Cable length for LED modules: 10 m with cables of cross-section 1.5 mm
• Supplied with terminal protection and cable clamps
• Opposite input and output terminals
• Cable section:
- Primary: 0.75 mm
– 1.5 mm
(rigid cables); 0.75 mm
2
2
- Secondary (RGB LED terminals): 0.5 mm
(flexible cables)
• Cable clamp on primary and secondary for cable diameters:
- Primary: min 4 mm - max 8 mm
- Secondary: min 4 mm - max 8 mm
• Screw fixing for power supply
• Protections: Thermal (auto-off reversible), short-circuit, overload
• Max. temperature of tc casing: 80°C
• Dimensions (l x w x h): 224 mm x 60 mm x 36 mm
ConfigURation.
foR tHe oPeRations of installation and ConfigURation, see tHe BY-me
sYstem instRUCtions manUal attaCHed to tHe ContRol Unit.
• Functional units: 1; the unit can belong to at most 4 different groups.
• Selecting the functional unit (configuration): during group creation, when the control panel
requires pressing the device button (it is recommended to configure the device with the
load OFF):
- Press the CONF button, the red LED will light up;
- with the red LED on, the control panel will configure the functional unit; at the end of this
operation the red LED will go out.
Viale Vicenza, 14 - 36063 Marostica VI Italy
Tel. +39 0424 488 600 - Fax (Export) +39 0424 488 709
www.vimar.com
2
– 1 mm
(flexible cables)
2
2
– 1.5 mm
(rigid cables); 0.5 mm
– 1 mm
2
2
2
ConneCtions
Example of connection to the By-me busbar.
L
N
L
N
+
Bus
-
Fig. 1. Wiring diagram for power supply 01877.
Before connecting the power supply to the power mains 230V~, select the rated output volt-
age 12-24 V
by means of the jumpers on the secondary side (Fig. 2).
-
+
24 V
12 V
+
R-
G-
B-
Fig. 2. Position of the jumpers to select the output voltage of 24 V

installation RegUlations

Installation should be carried out in compliance with the current regulations regarding the
installation of electrical systems in the country where the products are installed. Ensure clear-
ance around the appliance so there is sufficient ventilation.
There must be no dripping or splashes of water on the appliance.
01874
2
Ta: 45°C max
01875
A
A
01877
A ≥ 25 mm; B ≥ 100 mm
Fig. 3. Minimum distance between the power supply 01877 and the lamps and/or external
walls.
for all details on possible installation architectures, please refer to si-Connection dia-
grams for the relevant item code at www.vimar.com -> Products -> Product catalogue.

standaRd ComPlianCe

LV directive.
EMC directive.
Standards EN 61347-2-13, EN 62384, EN 61547, EN 61000-3-2, EN 61000-3-3, EN 55015,
EN 50428, EN 50491.
01877
-
+
+
R G B
R-
G-
B-
module RgB led
strip RgB led
Configuration button
Configuration LED
TP BUS terminals
To set the rated output voltage to 24 V
the jumpers as shown in the figure.
To set the rated output voltage to 12 V
the jumpers onto 12 V.
RGB LED module/strip output terminals
.
module
RgB led
B
01877
strip
RgB led
, set
, set