INFRASTAR
SAFETY PHOTOELECTRIC CELLS
D
I
M
E
N
S
I
O
N
S
TECHNICAL CHARACTERISTICS
Power supply: 24V AC./DC.
Relay contacts range: 1A max to 24V
Absorption: 60 mA.
Operation temperature: from -20° to +70°C
Material: ABS containers / polycarbonate cover
MAIN COMPONENTS
A) Circuit enclosure
B) Optoelectronic circuit
C) Cover with incorporated infrared screen
D) Cover fixing screws
ASSEMBLY DESCRIPTION
1 - Align and fix the photoelectric cells at a height of approx. 50 cm from the ground.
2 - Prepare the arrival of the cables.
3 - Then secure the container of the circuit (1) to the wall by using the appropriate screws supplied and adding anchors as
necessary.
4 - Continue making the connections requested (see back), and at the end mount the infra-red screen cover (C).
CS 36
B
A
ENGLISH
D
C
C
A
P
A
C
T I
Y
1
0
m