EZL 1030-20 L
The EZL 1030-20 L charging and transport case can house up to 20 HDE 1030
tourguide receivers (all versions) and one Mikroport SKM 1030 hand-held transmitter
with the corresponding L 1032 charger (the case can also be used for HDI 1029
infrared receivers, if required). The case comes fitted with two L 1030-10 charging
units for recharging up to 20 receivers.
Putting the charging unit into operation
Plug the mains connector into the mains
supply cable to any of the two L 1030-10 charging units
thus, the mains unit supplies both charging units. After approx. 2 seconds, the LED
"CHARGE"
lights up and the device is ready for operation.
As soon as one of the charging units is connected to the mains, the device automatically
switches to normal charging (16 hours). The red LED "CHARGE"
charging process is also indicated by the control LEDs
compartments.
Charging the receivers
Switch off the receivers and and insert them into the charging compartments.
Starting the charging process
By pressing button
process is indicated by the red control LEDs
and the LED "CHARGE"
The automatic charging process (timer-controlled) will be completed after 16
hours. The LED "CHARGE"
Trickle charging
After a charging time of 16 hours, the device automatically switches to trickle
charging. The LED "TRICKLE"
small current (1.5 mA) to maintain their voltage. There is no time limit to this type
of charging, it will not damage the accuplugs. Trickle charging ensures that your
receivers are always ready for use, even when they have not been used for a long
period of time.
Essential notes
The charging process "CHARGE" cannot be interrupted. By pressing button
again, the charging timer is reset and the charging process starts over again.
A power failure also resets the charging timer and the charging process starts
over again.
Switch off the receivers before starting the charging process!
For additional information on the use of the HDE 1030, HDI 1029, SKM 1030 and
L 1032 (incl. mains unit) please refer to the corresponding operating instructions.
Technical Data
Charging compartments
Charging current at normal/trickle charge 4.6/1.5 mA
Charging time
Power supply
Weight without receivers
Dimensions in mm
Available mains units:
, the normal charging process begins. The charging
.
lights up. The accuplugs will now be supplied with a
NT 92
NT 92-120
NT 92-UK
Always recharge the Accuplugs after use!
, then connect the mains unit's power
goes off.
EZL 1030-20 L
20
approx. 16 h
NT 92
approx. 5 kg
514 x 332 x 340
230 V, 50-60 Hz
120 V, 50-60 Hz
240 V, 50-60 Hz
The stethoset receivers, the hand-held
transmitter and the L 1032 charger are not
included in the supply schedule.
. They are interconnected,
lights up and the
at the occupied charging
at the charging compartments