Guardian Technologies AC4850PT Instrucciones De Uso Y Cuidado página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTAllING & RemovING uv-c bulb
1. Remove the Rear
2. After removing
Cover of the unit
by pushing Lock &
Release Button.
4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and
pulling the bulb straight out of the unit. (Fig. 4).
1.866.603.5900 or visit us at www.guardiantechnologies.com to
5. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit. .
E-8
3. After removing the
Combination Filter,
the Rear Cover
use a Philips head
from the unit,
screwdriver to
remove the
remove two (2)
Combination Filter.
screws and detach
the UV-C Metal
Shield.
Pull UV-C Bulb
straight out of unit.
ImpoRTANT
:
The UV-C Bulb should be replaced every 10 - 12
months depending on use. Please contact Customer Service at
purchase a replacement bulb.
Replacement uv-c bulb: lb4000.
cleANING & mAINTAINING
The combINATIoN fIlTeR
The air purifier should be cleaned at least once every month and the outer Pre-/
Charcoal Filter attached to the HEPA/Anti-Mite Filter should be cleaned every month.
More frequent cleaning may be required depending on environmental conditions.
pRe-/chARcoAl fIlTeR
Remove the Pre-/Charcoal Filter from the velcro strips on the True HEPA/Anti-Mite Filter.
(Fig. 6) Clean with the brush attachment of your vacuum cleaner. This will remove lint and
dirt. After cleaning, reattach the Pre-/Charcoal Filter to the True HEPA/Anti-Mite Filter.
TRue hepA/ANTI-mITe fIlTeR
Remove the Combination Filter from the back of unit.
Remove the Pre-/Charcoal Filter to expose the HEPA/Mite Filter.
When the HEPA/Mite Filter turns from white to grey or black it should be replaced with
a new one. If the HEPA/Mite Filter is still white, it does NOT need to be replaced.
ImpoRTANT
:
Do NOT try to wash and re-use the Combination Filter. Please contact
Customer Service at 1.866.603.5900 or visit us at www.guardiantechnologies.com to
purchase a replacement filter.
Replacement filter: fIlTeR b peT (flT4850pT)
NoTe
: The Combination Filter is one filter. The multiple layers include: the Pre-/Charcoal
Filter and the True HEPA/Anti-Mite Filter.
AIR puRIfIeR
Use a clean, dry, soft cloth to wipe the external surface of the unit.
NoTe
: Do NOT stick any foreign objects or your fingers inside of the unit.
cAuTIoN
: Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on
and/or in the unit while cleaning as they will damage the product.
NEVER use alcohol or other solvents.
fIG. 6
E-9

Publicidad

Tabla de contenido
loading

Tabla de contenido