TECHNICAL DATA

MAINS VOLTAGE
230 V ~ 50 Hz
(RC 130i, RC 230i, RC 280i)
MAINS VOLTAGE (RC 230i UC)
12 - 36 V = / 12 - 24 V ~
130° (1 x 130° can be set independently) and 360°creep zone protection
FIELD OF DETECTION
230° (2 x 115° can be set independently) and 360°creep zone protection
280° (3 x 95° can be set independently) and 360°creep zone protection
RANGE
approx. 20 m, at an installation height of 2.50 m
SETTINGS
Mechanically using the setting controls, electronically using the infrared remote control
SWITCHING CAPACITY
230 V ~ 50 Hz, 2300 W/10 A (cos φ = 1), 1150 VA/5 AX (cos φ = 0,5)
(RC 130i, RC 230i, RC 280i)
SWITCHING CAPACITY (RC 230i UC)
12 - 36 V = / 12 - 24 V ~, 10 A (cos φ = 1), 5 AX (cos φ = 0,5)
MAX. INRUSH CURRENT
100 A/250 µs
TIME SETTING
Impulse/approx. 15 seconds - 30 minutes
LIGHT EXPOSURE VALUE APPROX.
2 - 2500 LUX
PROTECTION TYPE/CLASS
IP 54, II
OPERATING TEMPERATURE RANGE
-25 °C...+55 °C
CASING
UV-stabilised polycarbonate
white, similar to RAL 9010, brown, similar to RAL 8017,
COLOUR
black, similar to RAL 9005, Stainless steel look
APPROX. DIMENSION
Width 78 mm, Height 105 mm, Depth 135 mm