9. Holiday setting
Press
button to enter into the holiday start date setting, at this moment 1~3 is bright, hour
and minute blink with display 20:18, press
ed, press
to enter into month setting, at this moment hour blink, press
month. After adjustment completed, press
adjust date. After adjustment completed, press
his moment 4~7 is bright, hour and mminute blink with display 20:17,the setting method is same
with holiday start date setting.
After the holiday close date setting completed, "temperature" blink to set temperature, initial is
"--:--"which means the unit is off when holiday start. If use press
ture, then unit work with set temperature when holiday start. After temperature is setted, press
button to exit the setting. If the holiday setting is successfully, then
This functions is one time timing, after setting successful, the unit will work according to the set
requirements: the unit will execute the shutdown command at 23:00 on the vacation start date.
And the unit will execute the switch on command at 01:00 on the vacation finish date (according
to the parameters before shutdown).
10. Vacation setting cancelling
After timing setting successful, press and hold the
(if without the
button, press the
and
cancelled.
11.The priority of vacation mode and weekly timer
The vacation setting priority is higher than the weekly time setting. When the vacation starts and
the shutdowncommand is executed, the weekly timing setting is no longer executed as well.
When the vacation ends, the switch on command will be executed firstly, then the weekly timing
function is executed.
Vacation mode is prior to weekly timer mode. When the machine power off according to the
vacation setting, the weekly timer settings are invalid. After vacation period and machine is
power on, it would works according to the weekly timer settings.
12.Sterilization functionSterilization function is divided into manual and automatic. The wired
controller for domestic market is a manual one,automatic invalid (parameter F25, 1). The one for
oversea market has manual and automatic (parameter F25, 0). During sterilization operation,
the sterilization sign is light on, and when sterilization is completed, the sterilization sign will light
off.
V.2
and
to adjust year. After adjustment complet-
and
to enter into date setting, press
and
to enter into holiday close date setting, at
button to set tempera-
is bright.
button at the same time for 3 seconds
buttons at the same time). The time setting is
25
13.Manual sterilization
Press the
button on panel or press and hold the
1 second, the machine would run sterilization function according to the pre-set sterilization
to adjust
water temperature (default 60℃, ranges 60~80) and sterilization hot water preservation time
to
(default, ranges 0~60), the sterilization symbol would displayed on the screen.
14.Automatic sterilization
When the machine power on, the controller would record the automatic sterilization period. If
time interval is greaterthan the sterilization period, it would start sterilization since the time
interval bigger than the sterilization starting tim(default 7 days, ranges 5~10 days; default 1:00,
setting ranges 0~24 hours). And the sterilization operates according to the set sterilization
water temperature(default 60℃, setting ranges 60-80℃)and default sterilization hot water
preservation time (10minutes, setting ranges 5~60 minutes).
15.Parameter inquiry
Press and hold Reset button for 5 seconds, enter into parameter inquiry. Code Fxx would be
displayed on time area, xxis two digital numbers which represents parameter code. The specific
value of the parameter would be displayed on the temperature zone area. Press button the
or
to select and display the parameter.
16.Parameter recovery
Under none set state, press and hold the
dEF would be displayed on the panel. Press the
ered to factory default settings. (Note: please check the factory default parameter in factory
parameter settings).
17.Manual compulsive defrost
Press and hold the
the coil temperature is higher than the exit defrosting temperature, it will not enter defrosting.
18.Safety lock function
If there is no any operation in 2 minutes, system would automatically lock all the buttons. Then
all the buttons areinvalid. Press and hold the
to release the lock.
19.Check the water tank bottom water temperature
Press buon + and – simultaneously to check it.
and
and
buttons simultaneously for 1 second, word
button, all the parameters would be recov-
buttton for 10 seconds, then system would be forced to defrost. When
and
buttons at the same time for 3 seconds
26
buttons simultaneously for
V.2