SP100/120/150 & TP120
SX100/120 & TX120
Getting Started
• Install the DicksonWare™ Software.
• Connect the cable (supplied with the software) to the
logger and to a working serial port on your computer.
• Click the Setup button. When the setup window
appears, all fields should be automatically filled in,
this will confirm that DicksonWare™ has recognized
the logger. Should all fields remain blank, refer to "No
Communication" in the Trouble Shooting section of
this manual. Once DicksonWare™ recognizes the
logger, press the Clear button. This will delete all data
currently stored.
Useful Features
Delayed Start: Program how many Days, Hours and
Minutes must expire before your unit begins logging.
Real Time Monitoring: Monitor and graph your
process as it happens and print and save from real
time screen. (This feature should be used sparingly
as it causes the battery to drain quicker)
Customize Graphed Data: DicksonWare™ calculates
Min, Max and Average of all data collected. Customize
Specifications
Operating Range
Internal
Temperature Sensor
Temperature Sensor
Internal Temperature ±1.8°F (14 to 176°F)
Accuracy
Accuracy
External
Temperature Sensor
Temperature
External Temperature
Accuracy
Accuracy
R/H Sensor Type
R/H Sensor Type
% RH Accuracy
Storage Capacity
(Sample Points)
(Sample Points)
Resolution
DICKSON
DICKSON
Logger Operation
SP100
-40 to +176°F
(non-condensing)
(non-condensing)
Digital Sensor
±3.6°F (-40 to 14°F)
N/A
N/A
±3.6°F (-40 to 248°F)
N/A
N/A
32,000
0.1˚F
• The logger is now sampling and ready for use. The
default sample interval is 1 minute. Verify that the
indicator light is flashing every 10 seconds. You may
choose to change Default settings for sample interval
and start-date and time. When changing these
settings, the logger will automatically go through the
clear process to accept your changes.
Note: To conserve battery life when storing unit, press
the Setup button and select the shortest Sample Interval
and Stop When Full in the Samples section or remove the
battery for SX100, SX120 and TX models.
data by eliminating unnecessary data points and
customize Min, Max and Average to show only desired
information.
Export Data: A snapshot of your graph or a real-time
graph of points can be easily exported to other
programs such as Excel™ or PowerPoint™.
** CLICK ON THE FEATURES BUTTON IN THE **
SOFTWARE FOR DETAILED INSTRUCTIONS ON
HOW TO USE ABOVE FEATURES AND MORE.
SP120
-40 to +176°F
(non-condensing)
(non-condensing)
Digital Sensor
±1.8°F (14 to 176°F)
±3.6°F (-40 to 14°F)
Thermistor
±1.8˚F (-4 to +176˚F)
N/A
N/A
32,000 div. x2
0.1˚F
rev. 06/04
SP150
-40 to +176°F
(non-condensing)
(non-condensing)
Digital Sensor
±1.8°F (14 to 176°F)
±3.6°F (-40 to 14°F)
Thermocouple
±1.8˚F Full Range
(Unit Only)
(Unit Only)
N/A
N/A
32,000 div. x2
0.1˚F
TP120
-40 to +176°F
(non-condensing)
(non-condensing)
Digital Sensor
±1.8°F (14 to 176°F)
±3.6°F (-40 to 14°F)
N/A
N/A
Monolithic
±2% @ 73˚F
(0 to 95%)
32,000 div. x2
0.1˚F / 0.1% R/H

Publicidad

loading

Resumen de contenidos para Dickson SP100

  • Página 1 DICKSON DICKSON SP100/120/150 & TP120 SX100/120 & TX120 Logger Operation Getting Started • Install the DicksonWare™ Software. • The logger is now sampling and ready for use. The • Connect the cable (supplied with the software) to the default sample interval is 1 minute. Verify that the logger and to a working serial port on your computer.
  • Página 2 Troubleshooting No communication • Sampling may not be activated. To start sampling • Verify that you have the correct version of Dickson clear the memory. software installed on your PC. Version 5.0.1.4 or • Condensation may have formed on the unit. Place higher is required for models SP100, SP120 and TP120.
  • Página 3 FONCTIONNEMENT DE L’ENREGISTREUR PROFESSIONNEL SP100/120/150 & TP120 SX100/120 & TX120 Mise En Marche actuellement en mémoire. • Installez le logiciel DicksonWare. • Raccordez le câble (fourni avec le logiciel) à • L’enregistreur est maintenant en phase l’enregistreur et à un port sériel en bon état de d’échantillonnage est de 1 minute.
  • Página 4 Comuníquese con la fábrica para un numero de de compra antes de emitir un número RA. Note: Dickson no se hace responsable de los daños Autorización de Devolución (RA por sus siglas en inglés) antes de devolver cualquier instrumento. Se le pedirá el que resulten de fallas o el mal funcionamiento de sus número de modelo, número de serie y número de orden...

Este manual también es adecuado para:

Sp120Sp150Tp120Sx100Sx120Tx120