Install the new handle (6.A) and fasten it using
the grub screw (6.C), complete by inserting the
cap (6.B). To replace the screw down (6.H),
remove the cap (6.B) and the grub screw
(6.C) and pull out the handle (6.A). Once the
plate (6.D) has been removed, screw on the
stop cocks (6.I) in clockwise direction using a
screwdriver, then disassemble the screw (6.E),
the joint (6.F) and the protection cylinder (6.G).
Using a wrench, remove and replace the
screw down (6.H). Carefully clean the support
surfaces of the sealing gaskets and reassemble
in reverse order.
FIG. 07
To replace only the handle (7.H) follow the
instructions given below:
Pull out the cap (7.F), loosen the grub screw
(7.G) and remove the handle (7.H).
DO NOT move the bar of the new cartridge
(7.O) so as to not compromise the calibration.
Assemble the new handle (7.H) and lock it with
the grub screw (7.G). Complete the installation
by inserting the cap (7.F).
To replace the thermostatic cartridge (7.O)
remove the cap (7.B), loosen the grub screw
(7.C) and pull out the handle (7.A). After
disassembling the plate (7.D) screw on the
stop cocks (7.Q) in clockwise direction using
a screwdriver.
To replace the thermostatic cartridge with the
handle (7.E) follow the instructions given below:
remove the grub screw (7.P) and pull out the
thermostatic cartridge with the handle (7.E).
Install the new assembly (7.E) into the faucet
housing carefully aligning the positioning hole
with the housing of the grub screw (7.P). Tighten
the grub screw without forcing it to prevent
malfunctioning or damages.
To replace only the thermostatic cartridge (7.O)
follow the instructions given below:
Remove the grub screw (7.P) and pull out of the
body the thermostatic cartridge with the handle
(7.E). Remove the cap (7.F) from the assembly,
loosen the grub screw (7.G) and pull out the
handle (7.H). Disassemble the ring (7.I), the
lock nut (7.L), the peg (7.M) and the spacer
(7.N) from thermostatic cartridge (7.O).
Based on its policy of steady development Fortis reserves the right to change the characteristics
of the products without notice and therefore the images and data contained in this catalogue may vary.
Istruz. art. 8969000.indd 7
Install the new cartridge (7.O) in the faucet
housing aligning the positioning hole with the
grub screw housing (7.P). Tighten the grub screw
without forcing it to prevent malfunctioning or
damages.
DO NOT move the bar of the new cartridge
(7.O) so as to not compromise the calibration.
Install the temperature adjustment lock nut
(7.L) as shown, then carefully tighten the peg
(7.M) inserting the spacer (7.N) and assemble
the handle (7.H) positioning the ring (7.I) in
between. Lock it with the grub screw (7.G) and
complete by inserting the cap (7.F).
Once completed the replacement, remove the
stop cocks (7.Q) turning them in anti-clockwise
direction using a screwdriver. Reassemble the
plate (7.D), fit the handle (7.A) and lock it with
the grub screw (7.C). Complete the assembly
inserting the cap (7.B).
FIG. 08
The figure shows the faucet correctly assembled.
Start the water flow by rotating the handle (8.A)
by 90° clockwise, adjust the temperature using
the handle (8.B).
MAINTENANCE OF THE SURFACES
Before cleaning, make sure the faucet is cold
(heat wears the surface of the faucet down). Do
not use products containing acids or corrosive
substances. Wipe the faucet daily with a soft
cloth. Do not use steel wool or metal pads,
abrasive sponges or similar products. Right
after cleaning rinse off the detergent residues
with cold water. Damages to the faucets caused
by incorrect treatment are not covered by the
warranty.