English
INSTALLATION INSTRUCTIONS
Water Supply
Recommended
Maximum
Hot Water Temperature
65 C° (~150F)
80 C° (~175F)
Working Pressure
3 BAR (~45PSI)
5 BAR (~75PSI)
In case of pressures over 5 BAR (~75 PSI), we
Warning!, Do not force the screw (3.D).
recommend to use a pressure reducer.
Excessive tightening can affect the correct
Before proceeding with the assembly, purge the
function of the system or damage it. The
hot and cold water pipes so as to avoid the
thermostatic cartridge is equipped with a safety
accumulation of dirt and impurities that could
anti-scalding retainer set at 100°F (38°C). For
affect the function of the faucet.
higher temperatures push the button on the
adjustment handle. In case of hot or cold water
FIG. 01
pressure failure, the flow will automatically stop.
Remove with a screwdriver the protection covers
With a screwdriver loosen the stop cocks (3.H)
(1.A). Use the plug (1.B) if necessary.
in anti-clockwise direction.
FIG. 02
FIG. 04
Fit the faucet body to the wall with the shower
Remove the protection tape of the adhesive
outlet pointing upwards, connect the hot water
sponge (4.D) and apply it on the back of the
supply to the left inlet and the cold water supply
plate (4.C).
to the right one.
Fit the sliding flat washers (4.B) and (4.A) on
The depth of the wall niche must correspond
the plate (4.C) and install it on the thermostatic
(wall coating included) to the tolerance given
body till it is flush to the wall.
by the MIN/MAX references given on the
plastic cover (2.A).
FIG. 05
Once all connections have been carried out,
Control handles installation.
activate the faucet at the working pressure
For the upper portion with the stop cock, follow
(we recommend maintaining the water flow
the instructions given below:
for a few minutes so as to purge the system
Position the protection cylinder (5.N) on the
from any debris and/or dirt inside the piping).
screw down. Fit the insert (5.M) on the cartridge
Temporarily remove the protection cover (2.A)
bar so as to obtain the correct alignment once
to check if there are leakages and if the system
the handle (5.G) is installed, then lock it using
works regularly, reinstall the protection cover
the included screw (5.L).
(2.A) and finish the external wall surface.
Position the handle (5.G) and tighten the grub
screw (5.I). Complete the operation by fitting
FIG. 03
the finishing cap (5.H).
Remove the protection cover (2.A) as shown
For the lower portion with the thermostatic
in FIG. 02. With a screwdriver turn the stop
cartridge, follow the instructions given below:
cocks (3.H) clockwise, loosen the fitting screw
fasten the peg (5.E) on the thermostatic
(3.D) using the proper wrench and pull out the
cartridge bar and fit the spacer (5.F). Install the
test plug (3.E). Insert the o-ring (3.C) and the
handle (5.A) putting the ring (5.D) in between
sleeve (3.B) on the thermostatic body. Fit the
without moving the bar so as to not compromise
o-ring (3.G) into the housing on the faucet body
the cartridge calibration. Tighten the grub screw
and assemble the protection cylinder (3.F). Use
(5.B) and place the finishing cap (5.C).
a small quantity of the special grease included
FIG. 06
to lightly lubricate the o-rings of the thermostatic
cartridge (3.A). Insert the cartridge in the faucet
To replace only the handle (6.A) follow the
housing carefully aligning the positioning hole
instructions given below:
with the housing of the fitting screw (3.D), then
Remove the cap (6.B), loosen the grub screw
tighten the latter.
(6.C) and pull out the handle (6.A).
Istruz. art. 8969000.indd 4-6
FIG. 01
Minimum
15 C° (~60F)
0.5 BAR (~7PSI)
FIG. 03
FIG. 05
FIG. 02
FIG. 06
FIG. 04
FIG. 07
FIG. 08
P U R O
D E S I G N
I T A L I A N O
26/04/11 11:07