2nd EDITION SYSTEM PROGRAMMING
EXAMPLES
1. Switching staircase lights on for 60s after
receiving commands from door phones in
column 1 in the system.
Program the special decoder as follows:
Toggle
M0↵
Time: 60s
D60↵
Control: column
O1↵
Column codes 1
C1000X1↵ (1)
Deactivated function buttons F1A0↵; F2A0↵;
F3A0↵; F4A0↵
(1) If the special decoder was previously
programmed with codes in memory locations
X2, X3, X4, reprogram these locations with
the same value as cell X1 to avoid undesired
activation.
2. Switching lights in common areas for 90s
after receiving commands from door phones
in columns 2, 3 and 4 in the system and
switchboard button F1.
Program the special decoder as follows:
Toggle
M0↵
Time: 90s
D90↵
Control: column
O1↵
Column codes 1
C2000X1↵; C3000X2↵;
C4000X3↵ (2)
Function button F1 active
F1A1↵; F2A0↵;
F3A0↵; F4A0↵
(2) If the special decoder was previously
programmed with codes in memory location
X4, reprogram this location with the same
value as cell X1 (or X2 or X3) to avoid
undesired activation.
3. Switching lights in common areas for 50s
after receiving commands from main calling
stations with ID = 1 and ID = 2 only.
Program the special decoder as follows:
Toggle
M0↵
Time: 50s
D50↵
Control: single
O0↵
Codes ID=1 and ID=2
P01X1↵; P02X2↵ (3)
Deactivated function buttons F1A0↵; F2A0↵;
F3A0↵; F4A0↵
12
(3) If the special decoder was previously
programmed with codes in memory locations
X3 and X4, reprogram these locations with
the same value as cell X1 (or X2) to avoid
undesired activation.
4. Switching lights in common areas for 35s
after receiving commands from all main
calling stations in the system and from
switchboard button F4.
Program the special decoder as follows:
Toggle
M0↵
Time: 35s
D35↵
Control: column (*)
O1↵
Main codes (*)
P01X1↵ (4)
Function button F4 active
F1A0↵; F2A0↵;
F3A0↵; F4A1↵
(*): The main calling stations are considered
as belonging to the same column (different
from all other columns in the system).
(4) If the special decoder was previously
programmed with codes in memory locations
X2, X3, X4, reprogram these locations with
the same value as cell X1 to avoid undesired
activation.
5. Switching
all
lights
on/off
following
command from all door phones and calling
stations (switchboard F1 switches on and
F4 switches off).
Program the special decoder as follows:
Bistable
M1↵
Time: indifferent
Do not program
Control: Any
O2↵
Codes: indifferent
Do not program
Function buttons F1 and
F1A1↵; F2A0↵;
F4 active
F3A0↵; F4A1↵
DS1072-019
DS1072-019
13