User Guide Riva Viridion
5.3.4. Regeneration start time
Set the regeneration time. Regeneration will start when a delayed time, a cubic meter or a
calendar override start is enabled.
A
Use
to modify the digit.
B
Press
to pass to the next digit.
C
Press
to validate.
5.3.5. End of basic programming
NOTE
The controller saves the modifications and return automatically to service mode.
End of programming and modifications saving:
6 .
Startup
1.
Fill the brine tank in the cabinet with salt.
2.
Adjust the safety brine valve in the brine well to make sure the overflow elbow is installed above the float level.
3.
After the softener has been running a few minutes in service, proceed to hardness test on outlet water to make sure the
water is treated as per requirements, and eventually adjust the mixing device accordingly.
NOTE
Pentair advise to set a residual hardness between 50 and 100 mg/L of CaC0
7 .
Operation
7.1.
Display
7.1.1. During operation
• In service in time clock control mode:
the day and the current time in 24 hours are displayed.
• In service in volumetric control mode:
- the remaining volume capacity and the animated graphic gauge are displayed.
- this display alternate with the display of time clock control mode.
7.1.2. During regeneration
The following information are displayed on the screen:
• the regeneration symbol;
• a "#C" to show the current cycle;
• the total regeneration time remaining in minute.
14 / 108
.