Step 5. Make certain no bare conductors are exposed after attachment
to terminals. Replace terminal block cover when wiring is completed.
Step 6. Fixtures may also be daisy-chained by routing Class 2 12V AC
wiring from fixture to fixture (Refer to wiring diagram). Always connect
cable wires to adjacent terminals on the far right or far left side of the
terminal blocks. Tighten all terminal block screws to 4 In-lb minimum.
Step 7. Push excess wire into opening in mounting surface, displace
fixture coil springs as shown, (Fig. 4) insert fixture into opening.
Springs will recoil to hold fixture in place. Make certain wires are
contained behind the mounting surface and not damaged in any way.
Step 8. Gimbal fixtures may be adjusted to direct light as desired.
Remove fixture from mounting surface, adjust light aiming by rotating
lower housing to desired position and re-install. Make certain wires are
not twisted or damaged as a result of the re-aiming.
Step 9. Complete installation of all fixtures before restoring
electrical power.
WIRING DIAGRAM
DAISY-CHAINED FIXTURE(S)
(OPTIONAL)
WARRANTY
Juno Lighting Group provides five year limited warranty on LED components from date of purchase. Juno Lighting Group's obligation
is expressly limited to repair or replacement, without charge, at Juno Lighting Group's factory after prior written return authorization has
been granted. This warranty shall not apply to products which have been altered or repaired outside of Juno Lighting Group's factory.
This warranty is in lieu of all other warranties, expressed or implied, and without limiting the generality of the foregoing phrase, excludes
any implied warranty of merchantability. Also, there are no warranties which extend beyond the description of the product on the
company's literature setting forth terms of sale.
Product Services Phone (888) 387-2212
1300 South Wolf Road • Des Plaines, IL 60018
Phone (847) 827-9880 • Fax (847) 827-2925 • www.junolightinggroup.com
INSTALLATION INSTRUCTIONS
Figure 4
12V SECONDARY LEADS
MINI LED DOWNLIGHT
OR GIMBAL FIXTURE
© 2016 Acuity Brands Lighting, Inc.
CLASS 2
12V AC OUTPUT
TRANSFORMER
Rev 7/14