Keep the tube clean and free of dirt to ensure a smooth operation of the plant.
Clean the surface of the guide rollers of accumulated debris.
Regularly check the air fittings for looseness, leaks, cracks or damage.
Occasionally check the mounting hardware for looseness or damage.
16
DISPOSAL
Observe the national waste disposal regulations. Never dispose of the
machine, machine components or equipment in residual waste. If necessary,
contact your local authorities for information on the disposal options
available. If you buy a new machine or an equivalent device from your
specialist retailer, he is obliged in certain countries to dispose of your old
machine properly.
17
TROUBLESHOOTING
The air supply necessarily interrupt when
repair work. Disconnect hose from the air
Trouble
It winds not completely
back
Locking will not work
Leaking hose
HOLZMANN MASCHINEN GmbH
Possible cause
Coiled tubing unevenly
At low spring tension
To severe replacement hose
Adjustable hose stop ring
Hose rolled up too fast
Hose reel mounted incorrectly
Hose released too quickly
damaged arresting
damaged hose
Loose hose clamp
Worn rotating body seal
www.holzmann-maschinen.at
adjustment, maintenance,
supply!
Solution
Roll up hose evenly
replace spring
Use appropriate replacement hose
Adjust hose stop ring in the correct
position
Roll up hose evenly slowly
See Chapter 6 Assembly
Lead to lock tube slowly
replace locking unit
replace hose
Fix or replace hose clamp
Replace rotating body seal
LSR10HQ, LSR15HQ
DISPOSAL
and
16