7.3 Water Full alarm
The inner water tray inside the air-conditioner has one water level safety switches, it con-
trols water level. When water level reaches an anticipated height, the water full indicator
lamp lights up. (If water pump is damaged, when the water is full, please remove the rub-
ber blockage at the bottom of unit, and all water will be drained outside.)