Kenmore 152.23151910 Manual De Uso Y Cuidado página 29

Parrilla a gas lp con 4 quemadores y carro lateral
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Grill Specifications
Burner
Injector Size
Gas/Pressure
Input Rate
Standard
TECHNICAL AND SERVICING INFORMATION
This appliance is designed for outdoor use only using Propane gas at a supply pressure of 11" per WC
and must be serviced by a competent person in accordance with the instructions included. Please read all
accompanying documentation carefully.
TROUBLESHOOTING
Problem
Burner will not light using
the ignition system
Low flame or flashback
(fire in burner tube - a
hissing or roaring noise may
be heard
Gas valve knob difficult to
turn
4 Burner
1.0 MM
11" per W.C
11,700 BTU/HR*3 (main)
ANSI STD Z21.58-2018 Outdoor Cooking Gas Appliances
Possible Cause
LP gas cylinder is empty
Faulty regulator
Obstructions in burner
Obstructions in gas jets or gas hose
Electrode wire is loose
Electrode or wire is damaged
Obstructions in burner
Obstructions in gas jets or
gas hose
Windy conditions
Gas valve jammed
14,000 BTU/HR*1 (searing)
Solution
Replace with full cylinder
Have regulator checked
or replace
Clean burner
Clean jets and gas hose
Reconnect wire
Change electrode and wire
Clean burner
Clean jets and gas hose
Use grill in a more
sheltered position
Replace gas valve
29

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido