TP1
1.
GENERAL DESCRIPTION
TP1 is a proximity reader with data output in Wiegand or Dataclock format. It can be connected to M2P access control units and to other units that accept
the data format generated by the reader.
TP1 works with the proximity badges and tags TP.
All the electronic components and the antenna are assembled in an entirely sealed container with high resistance to atmospheric agents (IP67).
The TP1 reader is equipped with a two-colour red/green LED and a buzzer to indicate the various functioning phases.
To install, assemble the reader and connect the cable to the access control unit in accordance with the instructions shown below.
2.
TECHNICAL FEATURES
Power supply
Average absorption
Reading technology
Reading range
Signalling
Connection distance to the host
Insulation class
3.
CONNECTIONS
RED
GRAY or BLACK
GREEN
WHITE
ORANGE
CYAN or BLUE
YELLOW
BROWN
VIOLET
PINK
4.
FUNCTIONING
•
Power up the reader. The buzzer beeps once and the led turns on (red)
•
Place a badge, a tag or a double technology transmitter in front of the reader: the buzzer sounds, the LED turns into green and the code of the
badge is output at DATA0-DATA1 in Wiegand 30 bit format. The LED remains green and the PRESENCE line (PINK wire) goes low (0V) as long as
the badge is hold in the field of the reader. The standby status of the PRESENCE line is high (5V)
5.
DATA FORMAT
If the MODE input (BROWN wire) is left unconnected or tied to 5VDC the output data format is Wiegand. If the MODE input is connected to GROUND the
output data format is DataClock.
While in Wiegand mode (BROWN wire unconnected or tied to 5VDC), if the WIEGAND FORMAT input (YELLOW wire) is left unconnected or tied to
5VDC, the data format at DATA0-DATA1 is 30-bit Wiegand. If the WFMT input is connected to GROUND, the data format at DATA0-DATA1 is 26-bit
Wiegand.
6.
LED DRIVING
If the ORANGE and CYAN wires are left unconnected or tied to 5VDC the status of the led is driven by the reader itself.
If one or both of the ORANGE and CYAN wires are connected to GROUND, the status of the LED changes as follows:
ORANGE wire
GROUND
GROUND
5VDC or floating
7.
TP1 ASSEMBLY INSTRUCTIONS
•
To assemble the reader, drill two 2.5 mm. holes in the support bracket for the fixing screws and one 6 mm diameter hole for the cable (fig. 1). Place
an insulating gasket around the hole. Hook-up the interface cable from the reader to the access control station and mount the reader using screws
with a max. diameter of 3 mm (fig. 2).
•
Fix the cover to the base, pressing until the hooks click into place (fig. 3).
•
Connect the reader to the host following the instructions in the table below and in the central unit installation manual. The table shows the
connections for the M2P units.
Keep in mind that installing the reader on metal surfaces could decrease the reading distance.
61622770 rev. 2 25/09/2012
12 VDC
20 mA
Proximity - 125 KHz
8 cm
Bicolour led (red/green), buzzer
100 meters max.
IP 67
12 VDC
GROUND
DATA0
DATA1
Red LED driving
Green led driving
WIEGAND FORMAT
MODE
Not used
PRESENCE
CYAN wire
LED status
GROUND
OFF
5VDC or floating
RED
GROUND
GREEN
MPROXMINI
RED
+12 Vdc
BLACK
GROUND
GREEN
DATA 0
WHITE
DATA 1
ENGLISH
M2000PE
M2000PE
PORT 1
PORT 2
18
9
15
6
17
8
16
7
2