12. Remove the test weight from the platform and zero the scale if necessary.
13. Again apply the test weight to each of the four corners to check that there is
no longer any variation. Repeat the above steps to account for any
remaining variation if required.
14. Once all variation has been removed, replace the rubber adjustment covers
on the loadbars.
15. Perform a calibration of the weigh scale using the test weight in the centre
of the platform. (Please refer to the calibration procedure technical note for
the weigh scale concerned for more detail on how to achieve this).
Page 6
3E1045 Gallagher Load Bar User Manual