Balance the Water

To find out if your pool water is balanced:
• take a water sample to your dealer to be tested regularly, or
• ask your dealer to recommend a pool test kit for water balance.
Element: pH
Range: 7.4-7.8
Element: Calcium Hardness
Range: 200-400 ppm
Element:
Total Alkalinity
Range: 80-150 ppm

Install the Cartridge

1
Install the cartridge after water is balanced. Refer to your Jandy
TruGuard vessel operating manual for additional instructions.
2
Superoxidize the pool water with chlorine according to manufacturer's
instructions to burn off contaminants and activate cartridge.
Important: Initial superoxidation with chlorine is required to burn off contaminants
and activate cartridge.
ENGLISH
If it's too low
How to fix
If it's too high
How to fix
If it's too low
How to fix
If it's too high
How to fix
If it's too low
How to fix
If it's too high
How to fix
Jandy
®
TruGuard
& Cartridge
The surface of your pool can become
etched. Metal parts in the pump and
plumbing will corrode.
Add pH increaser.
"Scale" forms on the surface of your pool.
The water can become cloudy. Equipment
can become damaged.
Add pH decreaser.
Water is less stable. In plaster pools, the
calcium is taken out of the plaster, causing
the surface to deteriorate.
Add calcium hardness increaser.
Rough, discolored deposits ("scale") will
form on the pool surface and inside the
pool equipment.
Drain or dilute the pool water. Consult
your dealer.
It provides no buffer so that you constantly
get fluctuating pH readings, which can
damage equipment and pool surfaces.
Use an alkalinity increaser.
White deposits ("scale") form on the tile
line. The plaster on the pool surface
becomes rough or discolored. The water
becomes cloudy or milky white.
Add acid to bring alkalinity down.