9. Warning
Be sure to verify the following before installing Hoymiles Microinverter System.
Verify that the voltage and current specifications of the PV module must match those of the
microinverter.
The maximum open circuit voltage rating of the PV module must within the operating voltage
range of the microinverter.
The maximum current rating at MPP is recommended to be equal to or less than the
maximum input DC current. But the maximum short circuit current must be equal to or less
than the maximum input DC short circuit current.
The output DC power of PV module is NOT recommended to exceed 1.35 times the output AC
power of the microinverter. Refer to "Hoymiles Warranty Terms & Conditions" for more
information.
8.1 DC Input
8.2 AC Output
Model
Commonly used module power (W)
Peak power MPPT voltage range (V)
Start-up voltage (V)
Operating voltage range (V)
Maximum input voltage (V)
Maximum input current (A)
Maximum input short circuit current
(A)
© 2019 Hoymiles Power Electronics Inc. All rights reserved.
MI-300T/MI-350T/MI-400T
MI-300T
Up to 380
Up to 440
(single panel)
(singe panel)
29~48
22
16~60
60
11.5
15
MI-350T
MI-400T
Up to 500
(singe panel)
33~48
34~48
22
22
16~60
16~60
60
60
11.5
12.5
15
15