Instructions for use (rev 290319)
5. PROGRAMMING
5.1. Alphanumeric display
There are two different display modes, which must be clearly differentiated:
A. The programming mode (initiated by pressing the key PROGRAMING
In this mode, you can select or modify the parameters in a program, which are displayed flashing.
To change the value of each parameter, press the
To move on to the next parameter, press the
Once you have programmed all the parameters on the page, you move on to the following page
by pressing the key
The programming mode comprises 5 pages.
B. The operating mode (not flashing)
The top line displays:
- the temperature in °C
- the vacuum in %
- the program number, from 0 to 99
NOTE: If the furnace is on "IDLE", press the
lower line displays: program name
5.2. STAND-BY key
When the furnace is on "IDLE" (with the platform in low position) press this key to switch to
"STAND-BY" position: the platform closes, and the temperature is maintained at 300°C.
When the furnace is not used for 5 minutes, the platform closes automatically.
To exit the "STAND-BY" position, press the
NOTE: You can change the standby temperature and the automatic standby delay timer (see
chapter 7 - secondary parameters.
5.3. STAR/STOP key
Press this key to initiate the firing cycle.
By pressing the key a second time during the cycle, you interrupt the firing operation and return
the furnace to "IDLE" (platform in low position).
UGIN DENTAIRE
or
arrow.
arrow.
The lower line displays:
-
the ongoing phase
-
the time count
or
arrow to change the program number. The
key again.
ARTIS NEO
)
25