Start The Machine; Stop The Machine; Maintenance; Spray Tip Maintenance - GreenWorks Tools GPW 1803 Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING
Do the instructions on the solution bottle to prepare
detergent.
If it is necessary, use a funnel to prevent the spill of
detergent. Clean and dry the spilled detergent when you fill
it.
Soap/detergent can only be applied with this machine when
the black nozzle(75 degree) is installed.
1. Put the machine vertically on a flat surface.
2. Open the cap on the deterfent tank (5).
3. Put the detergent into the detergent tank (5).
4. Close the cap.
Do not let detergent dry on the surface to prevent streaks.
4.5

START THE MACHINE

CAUTION
Do not operate without the water supply connected.
CAUTION
Before you start the machine:
1. Turn the water supply on.
2. Pull the gun trigger to release air pressure.
3. If a stable stream of water come into view, release the
spray gun trigger.
1. Connect the machine to the power supply.
2. Set the power switch to the "ON" ( | ) position.
3. Turn the water supply on.
4. Pull the spray gun trigger.
4.6

STOP THE MACHINE

1. Release the spray gun trigger.
NOTE
NOTE
NOTE
English
2. Press down on the ON/OFF switch, once again, to set the
power switch to the "OFF" (O) position.
If you do not use the machine:
Stop the machine.
Turn the water supply off.
Disconnect the power cord from the outlet.
Pull the spray gun trigger to release the remaining
pressure from the machine.
Engage the trigger safety lock-out on the spray gun.
5

MAINTENANCE

Before maintenance, make sure that you
Stop the machine.
Wait until all the moving parts stop.
Disconnect the plug from the power source.
Do not use strong solvents or detergents on the plastic
housing or components.
Do not let brake fluids, gasoline, petroleum-based materials
touch the plastic parts. Chemicals can cause damage to the
plastic, and make the plastic unserviceable.
Replace the power cord by an approved service center.
5.1

SPRAY TIP MAINTENANCE

If there is too much pump pressure, the spray tip can become
clogged, you can feel a pulsing sensation while you pull the
spray gun trigger.
5.1.1

REMOVE THE SPRAY TIP

1. Pull back the quick-connect collar on the spray wand (2).
2. Remove the spray tip (11) from the spray wand (2).
11
WARNING
WARNING
WARNING
WARNING
WARNING
EN

Publicidad

Tabla de contenido
loading