MAINTENANCE
Periodically loosen the front knurled ringnut to bare the collet locking system.
Move the collet locking lever to position B (fig. 1) and blow a strong air jet into the collet.
TROUBLESHOOTING
The tool shank
does not lock
in the closed
collet.
The tool does not
rotate correctly and
the handpiece tends
to heat up.
TECHNICAL PARTICULARS
Maximum rotation speed
Handpieces various models
Maximum transmissible torque
Noise level
Vibrations
Connection transmission shaft side,
Dimensions
Weight
GUARANTEE CERTIFICATE
FARO offers the final customer a 6 month guarantee starting from the date of purchase.
Repairs under guarantee must be performed at FARO; expenses and transport risks are at the risk of the purchaser.
Repair under guarantee is considered valid only when:
− all sections of the certificate have been filled in and sent in advance to FARO by Fax (039.6010540).
The guarantee covers faults due to the bad quality of the material or manufacturing defects; in the case of valid
claims, the guarantee covers free repair or replacement. Claims for damages and/or interest are excluded.
The guarantee is not considered valid, at the sole discretion of FARO, if the fault is due to tampering, damage,
incorrect use, improper maintenance and normal wear and tear.
SELF-LUBRICATING HANDPIECE
Do not lubricate
21
- Make sure the shank diameter is compatible with the collet.
- Call our Service Department to have the collet calibrated.
- Clean the handpiece as explained under MAINTENANCE.
- Call our Service Department.
22
:
22000 rpm
:
for tools diameter 2,35 / 3 mm
:
4,9 Ncm
:
< 60 dB (A)
:
< 2,5 m / s
:
type slip / flexible / duplex / USA
:
length 154 mm - diameter 17 mm (mod. 010.000)
:
110 grams (mod. 010.000)
23
24
2