English; Service Life - OCENCO M-20.2 EEBD Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
E N G L I S H
OCENCO M-20.2 EEBD
EMERGENCY ESCAPE BREATHING DEVICE
INSTRUCTION
BOOKLET
P/N 340059, DWG C16141, Rev. B, ECN 3450
The Ocenco M-20.2 EEBD is a belt worn or stored,
compressed-oxygen, self-contained self-rescuer.
The M-20.2 EEBD instantly provides breathable
air, independent of the surrounding atmosphere,
to a person escaping from any area of toxic gas
or oxygen deficiency.
DONNING PROCEDURE
The following are the donning steps for the belt
worn configuration of the M-20.2 EEBD. If the
M-20.2 EEBD is wall mounted, first remove the
orange Secondary Container from the wall and
the M-20.2 EEBD from the orange Secondary
1
(Type"D")
CE 0194/EN 13794:2002
ISO 23269-1:2008
Container case. These five steps must be
practiced numerous times until they become
second nature.
1. Lift yellow lever and discard cover.
2. Remove unit by pulling yellow neck strap
upwards.
3. Insert yellow mouthpiece.
4. Fit yellow nose clip.
5. Inhale through mouth and escape.
To fit the neck strap, simply place the neck strap
over the head and pull upward on the o-ring to
shorten the neck strap.
To fit the face shield, simply pull the face shield
over the head and pull outward on the o-rings to
tighten the face shield around neck.
In the unlikely event that moisture on the inside
of the face shield distorts your vision, simply
press or rub face shield against the face with
your hand.

SERVICE LIFE

Service Life: the M-20.2 EEBD may remain in
service for fifteen years from the date of
manufacture, provided the conditions of use are

Hide quick links: