Error Messages and Recommended Action
Push the start button to reset the error signal. If in doubt, please contact the
manufacturer or local distributor.
Error and status messages
Permanent
Dark
Display of
Start
the
Possible cause and corrective action
Button
crucible
Crucible not mounted.
> Mount crucible and fill with oxalic acid
dihydrate.
Metallic material with special properties
over or under crucible.
> Increase distance to metallic material.
Red
Red
Overload with excessive material in crucible.
> Clean crucible in water and add correct
amount of oxalic acid dihydrate.
Foreign matter in crucible.
> Remove foreign matter, clean crucible
with water and fill with oxalic acid.
Device has been moved during the
treatment.
Blue
Red
Oxalic acid crucible is empty or has
insufficient amount.
Device has been moved during treatment.
White
Red
Device is cooling down, leave in place.
White
Blue
Flashing
34
Remove device from colony, place hot
crucible in container with water for cooling.
Leave device in the air to cool.
Violet
Blue
Device has overheated.
> Remove crucible. Extended period of
cooling of base required before the next
treatment.
Orange
Red
Device has not been used for more than
4 minutes and has switched off
automatically.
> Push and hold start button for 3 seconds.
Device turns into ready mode with all
displays shining green permanently.
Battery pack has been discharged
> Push start button to display battery
charge with one or no light shining green
replace with charged battery pack.
Battery pack is discharged and no further
treatment is possible.
> Replace with charged battery pack.