PROCESS VARS
GAS NAME
XXXXXXX
GAS VALUE
X.XX
HIGH ALARM
Y/N
LOW ALARM
Y/N
AUX ALARM
Y/N
ANALOG INPUT
X.XX MA
ANALOG OUTPUT
X.XX MA
URV
X.XX
LRV
X.XX
FAULT
Y/N
DISPLAY STATUS
GENERAL INFO
FAULT/STATUS
HISTORY
DISPLAY INFO
RS485
DEBUG MENU
MAIN MENU
PROCESS VARS
DEVICE STATUS
DISPLAY STATUS
DEVICE STATUS
FAULT/STATUS
DISPLAY SETUP
CALIBRATION LOG
DEVICE SETUP
DEVICE CAL
DISPLAY TEST
DISPLAY SETUP
ALARM SETTING
MODE SELECT
HART OPTION
RTC
RS485
INPUT LOOP CAL
CONTRAST CONTRL
OUTPUT MODE
BACKLIGHT CTRL
WRITE PROTECT
DEVICE SETUP
GAS NAME
XXXX
DETECTOR TYPE
DEVICE CAL
CALIBRATION
CAL GAS CONC
XXX.XX
DISPLAY TEST
SELF TEST
RESPONSE TEST
LOOP TEST
D/A TRIM
FAULTS
FAULTS/ STATUS
HIGH FAULT
ON/OFF
FAULTS
Y/N
LOW FAULT
ON/OFF
CALIBRATION LOG
CAL ID
XXXX
DATE
DD/MMM/YYYY
TIME
HH:MM:SS
ZERO
XXXX
SPAN
XXXX
DETECTOR TYPE
505 CH4 100 %LFL
CALIBRATION
EXECUTE
ABORT
SET 4-20 MA
3.5 MA
4 MA
6 MA
LOOP TEST
8 MA
10 MA
SET 4-20 MA
12 MA
14 MA
16 MA
18 MA
D/A TRIM
20 MA
ZERO TRIM
GAIN TRIM
HGH ALARM NE/NDE
ALARM SETTING
NE-NORMALY ENERGIZED
NDE-NORMALY DEENERGIZED
RST LATCH ALARMS
HGH ALARM LEVEL
XX.XX
HGH ALARM LATCH
Y/N
LOW ALARM NE/NDE
HGH ALARM NE/ND
LOW ALARM LEVEL
XX.XX
NE-NORMALY ENERGIZED
LOW ALARM LATCH
Y/N
NDE-NORMALY DEENERGIZED
LOW ALARM NE/ND
AUX ALARM LEVEL
XX.XX
AUX ALARM NE/NDE
AUX ALARM LATCH
Y/N
AUX ALARM NE/ND
NE-NORMALY ENERGIZED
NDE-NORMALY DEENERGIZED
MODE SELECT
HART DEVICE
PIR9400
C706X
505
NTMOS
CGS
GENERIC DEVICE
HART OPTION
TAG
XXXXX
DESCRIPTOR
XXXXX
DATE
DD/MMM/YYYY
MESSAGE
XXXXX
FINAL ASSY NUM
XXXXX
RTC
DISPLAYED
Y/N
SECONDS
XX
MINUTES
XX
HOURS
XX
DAY
XX
BAUD RATE
MONTH
XX
YEAR
XX
1200
2400
4800
9600
RS485
19.2K
BAUD RATE
PARITY
PARITY
POLL ADDRESS
XXXX
NONE
EVEN
ODD
OUTPUT MODE
STANDARD
REPLICATE
BACKLIGHT CTRL
OFF
ON
AUTOMATIC
WRITE PROTECT
CHANGE STATE
CHANGE PASSWORD
WRITE PROTECT
XXXX
GENERAL INFO
MANUFACTURER
MODEL
UD-10
TAG
XXXXX
TH
DESCRIPTOR
XXXXX
6901 WEST 110
STREET
DATE
DD/MMM/YYYY
MINNEAPOLIS, MN 55438
MESSAGE
XXXX
USA
FINAL ASSY NUM
XXXXX
DEVICE ID
XXXXX
FAULT
EE FAULT
ADC FAULT
24V FAULT
FLASH FAULT
RAM FAULT
WDT FAULT
12V FAULT
5V FAULT
3V FAULT
FAULT/STATUS
O/P LOOP FAULT
INPUT LOOP FAULT
OP MODE
XXXXX
FAULT
Y/N
STATUS
Y/N
STATUS
ANY FAULT
CAL ACTIVE
WARM UP
LOW RELAY ACTIVE
HI RELAY ACTIVE
AUX RELAY ACTIVE
CURRENT FIXED
MB WRITE PROTECT
HART SELF TEST
LON ATTACHED
RESPONSE TEST
MANUAL SELF TEST
INPUT HART
DISPLAY HISTORY
RUNNING HOURS
MAX TEMP
MAX TEMP TIME
MIN TEMP
MIN TEMP TIME
RESET MAX MIN
HISTORY
MAX RESET TEMP
MAX RESET TIME
DISPLAY HISTORY
MIN RESET TEMP
EVENT LOG
MIN RESET TIME
EVENT LOG
DISPLAY INFO
EVENT
XXXXX
DATE
DD/MMM/YYYY
RTC
TIME
HH:MM:SS
SERIAL NUMBER
XXXXX
I/O BOARD ID
XXX
MFG DATE
DD/MM/YYYY
F/W REV
XXXXX
RTC
UNIVERSAL REV
XXXXX
FIELD DEV REV
XXXXX
RUNNING HOURS
XXXXX
DISPLAYED
SECONDS
TEMPERATURE
XX.XX C
HEATER CTRL
AUTO/ON/OFF
MINUTES
HOURS
BACKLIGHT CTRL
AUTO/ON/OFF
INPUT VOLTAGE
XX.XX
DAY
MONTH
YEAR
RS485
BAUD RATE
XXXXX
PARITY
XXXXX
POLL ADDRESS
XXXXX
DEBUG MENU
HART ERRORS
XXXXX
MODBUS ERRORS
XXXXX
OUTPUT READBACK
XX.XX MA
ANALOG INPUT
XX.XX MA
Detector Electronics
17-Aug-11
505
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
XXXX
XX.XX C
XX:XX:XX
XX.XX C
XX:XX:XX
XX.XX C
XX:XX:XX
XX.XX C
XX:XX:XX
Y/N
XX
XX
XX
XX
XX
XX
3.25