Table 8: System Log System Event Codes
E
N
Displayed
Code
G
L
I
SLP
S
H
EPO
OFF

500 Specifications

Table 9: Specifications (Standard Product)
Model Number
Capacity
Nominal AC Input Voltage
AC Input Current
200 V input
208 V input
220 V input
230 V input
240 V input
AC Input Frequency
Efficiency on AC Line
Maximum Heat Output (on
AC Line)
Audible Noise on AC Line at
1 meter
Typical Runtime
6
Weight
(with Batteries)
Dimensions
(H x W x D)
1
For UT5K units with an optional L6-30 input plug and 200 V input, capacity is 4.55 kVA/ 4.55 kW.
For UT5K units with an optional L6-30 input plug and 208 V input, capacity is 4.75 kVA/4.75 kW.
2
The unit will operate on AC line at input voltages of 147 V to 276 V (at the default parameter settings).
3
For models with a standard battery charger.
4
Programmable range is 45 to 65 Hz. See Sections 302 and 303, parameters 16 and 17.
5
At 75% resistive load, batteries at full charge.
6
At 0.75 power factor.
What It Means
The UPS ran on battery power (inverter).
The UPS shut down, but the microprocessor stayed active (also referred to as "sleep" mode).
The UPS did a battery test.
The unit was not regulating power (for example, after a Low Battery shutdown).
The unit was placed into battery maintenance mode (see parameter 63), or the unit tested the BYPASS
light by briefly switching to internal bypass mode during a front key TEST (see Section 202).
Corrupted log.
The UPS shut down due to an Emergency Power Off signal sent to the unit's DB9 port.
The unit's keyswitch was turned off, or the unit sounded a Check Power Supply alarm (
UT3K
3 kVA/3 kW
2
3
17 amps
17 amps
16 amps
15 amps
14 amps
4
5
95%
539 BTU/hour
0.158 kW
Full Load:
19 minutes
75% Load:
26 minutes
50% Load:
43 minutes
215 lbs.
98 kgs.
UT4K
4 kVA/4 kW
200, 208, 220, 230, 240
22 amps
22 amps
20 amps
20 amps
19 amps
50/60 Hz ±3 Hz.
96%
569 BTU/hour
0.167 kW
40 dBA
12 minutes
17 minutes
28 minutes
280 lbs.
127 kgs.
29 in. x 10.5 in. x 25.75 in.
737 mm x 267 mm x 654 mm
20
A-19
UT5K
5 kVA/5 kW
8 kVA/8 kW
28 amps
45 amps
27 amps
43 amps
25 amps
41 amps
24 amps
39 amps
23 amps
38 amps
96%
711 BTU/hour
1138 BTU/hour
0.208 kW
0.333 kW
9 minutes
13 minutes
13 minutes
19 minutes
21 minutes
31 minutes
295 lbs.
490 lbs.
134 kgs.
222 kgs.
32 x 13 x 33 in.
813 x 330 x 838 mm
).
UT8K
96%