Special Functions; Accessories & Replacement Parts - Honeywell TH1000DV Serie Installation Guide

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Guide
Special functions
Early Start (Setup Function 13): Early start allows the heating or cooling to turn on before the
program start time, so the temperature is reached at the time you set.
Compressor Protection (Setup Function 15): Forces the compressor to wait a few minutes before
restarting, to prevent damage. During the wait time, the message Cool On or Heat On (heat pumps
only) will flash on the display.
Accessories & replacement parts
Please contact your distributor to order replacement parts.
Cover plate assembly* ........................................ Part Number 50002883-001
*Use to cover marks left by old thermostats.
Specifications
Temperature Ranges
• Heat: 40° to 90°F (4.5° to 32°C)
• Cool: 50° to 99°F (10° to 37°C)
Operating Ambient Temperature
• 32° to 120°F (0° to 48.9°C)
Shipping Temperature
• -20° to 120°F (-28.9° to 48.9°C)
Operating Relative Humidity
• 5% to 90% (non-condensing)
Physical Dimensions
• 3-7/16"H x 4-10/16"W x 1-3/16"D
87mm H x 119mm W x 30mm D
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
http://customer.honeywell.com
® U.S. Registered Trademark
© 2013 Honeywell International Inc.
69-2800EFS—01 M.S. 05-13
Printed in U.S.A.
Electrical Ratings
System
Voltage (50/60Hz)
Heat (1st stage)
(Powerpile)
Auxiliary heat
Cooling
Running Current
20-30 Vac
0.02-1.0 A
750 mV DC
100 mA DC
20-30 Vac
0.02-1.0 A
20-30 Vac
0.02-1.0 A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pro th2000dv serie

Tabla de contenido