Fulgor Milano CREATIVE CPH 401 G DWK TC Manual De Instrucciones página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
Adaptation to varius types of gas (Fig. 10)
Should the appliance be pre-set for a different type of
gas than available, procreed as follows:
• replace the injector (Fig. 7) with the corresponding type
of gas to be used (see table "User characteristics");
Mod. Dual
A
Mod. 2G
Minimum burner capacity regulation procedure
The procedure for acquiring the minimum capacities
allows the operator to change the minimum capacity
programmed, adapting every burner to the characteristics
of the gas distribution network to which the hob is
connected.
The procedure is activated by pressing the +A and –A
keys together with the +B key constantly for 3 seconds,
with the burners all switched off.
The activation of the regulation procedure is indicated
on the display with the word "MIN". It is now possible to
select the burner to regulate using the respective + and –
keys. After pressing one of the keys, the burner selected
will come on at minimum level and it will be possible to
increase or reduce the capacity to the minimum level
using the using the + and – keys for this burner. During
the display regulation procedure, the flame display levels
will show the indication - if the minimum level programmed
corresponds with the factory setting, and the indication will
change ^ or v in flashing mode, indicating a higher or lower
capacity than that programmed. The procedure ends by
pressing the PT key. The minimum capacity levels will
then be acquired and memorised by the device, and will
be used in the normal use of the hob.
Selecting the type of fuel gas
You can configure the cook top to work with different
gases (see table 1). To select the fuel gas to use, the
cook top must be on with all the burners off. Just press
B
the burner A, burner B and B- keys together for at least 2
seconds. When the fuel gas selection procedure starts,
the burner level display turns off and the timer display
shows "2020", "3029", "2525" or "2010", depending on
the current configuration in use. It is possible to select
the desired setting with the A+ and A- keys. To end the
procedure, you must press the PT key.
Using this function deletes any turn-off times that may
have been programmed for the burners.
Electronic self-test
The electronic cards are continuously checking their
status. If there are any hardware or board problems that
could affect the end-user's safety, the cook top goes
into a "safe" mode which closes the solenoid valves and
displays a code relative to failure.
Fig. 10
23
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Creative cph 402 g tc

Tabla de contenido